Document IIF
Séchoirs à déshumidification pour le bois difficile à sécher.
Dehumidifier dryers for hard-to-dry timbers.
Auteurs : CARRINGTON C. G., SUN Z. F., SUN Q., et al.
Résumé
Hard-to-dry timbers, such as Nothofagus fusca (New Zealand Red Beech) are prone to degrade during kiln drying unless they are predried slowly at low temperature. However, air-drying is uncontrolled, and typically takes 12-24 months for N. fusca. The paper assesses the design of a dehumidifier kiln for drying untreated N. fusca, based on a time-dependent process model. The energy use of the dehumidifier kiln is compared with a vented kiln having the same duty, and the cost of the dehumidifier kiln operation is compared with conventional air-drying. The results indicate that well designed dehumidifier dryers provide an opportunity to kiln-dry N. fusca under controlled conditions with significant savings in processing costs.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Dehumidifier dryers for hard-to-dry timbers.
- Identifiant de la fiche : 2000-1548
- Langues : Anglais
- Source : 20th International Congress of Refrigeration: Refrigeration into the Third Millennium.
- Date d'édition : 19/09/1999
Liens
Voir d'autres communications du même compte rendu (447)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d’air dans les laboratoires et l’industrie
- Mots-clés : Bois; Nouvelle-Zélande; Économie; Variété; Séchoir; Séchage; Programmation; Conditionnement d'air
-
A numerical model for a dehumidifier wood dryin...
- Auteurs : CARRINGTON C. G., SUN Z. F., BANNISTER P., BANSAL B.
- Date : 11/02/1996
- Langues : Anglais
- Source : Refrigeration, Climate Control and Energy Conservation.
- Formats : PDF
Voir la fiche
-
Energy saving potentials in laboratory faciliti...
- Auteurs : SANDRU E.
- Date : 10/06/2007
- Langues : Anglais
- Source : Clima 2007. WellBeing Indoors. Proceedings of the 9th REHVA World Congress [CD-ROM + Abstract book].
Voir la fiche
-
VARIABLE VOLUME SYSTEMS FOR LABORATORIES WITH F...
- Auteurs : MCGREGOR A.
- Date : 07/04/1991
- Langues : Anglais
Voir la fiche
-
Energy-efficiency strategies for clean rooms wi...
- Auteurs : TSCHUDI W., FAULKNER D., HEBERT A.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
Voir la fiche
-
Dynamic testing of desiccant matrices and compu...
- Auteurs : CZACHORSKI M., WURM J., WOREK W. M., MIERKE J., BRILLHART P.
- Date : 1997
- Langues : Anglais
- Source : ASHRAE Transactions.
Voir la fiche