Suivi sur le long terme d'un système de ventilation à récupération de chaleur résidentiel avec échange de chaleur par le sol.
Long term monitoring of residential heat recovery ventilation with ground heat exchange.
Numéro : pap. 397
Auteurs : CREMERS B.
Résumé
The monitoring of a demand controlled heat recovery ventilation system with ground heat exchange in a zero-energy building in Groenlo, The Netherlands, revealed interesting practical insights. A healthy indoor climate can be obtained with high comfort in terms of CO2 levels and supply air temperatures. The CO2 level stays well within the comfortable range in the living room and three bed rooms (parents, child, and guests), thanks to the demand controlled ventilation system. Supply air temperatures are in the comfortable range thanks to heat recovery in combination with ground heat exchange by an earth pipe. This is shown for ambient temperatures between -8°C and +33°C. The energy efficient behaviour is proven by the avoided heating load of 3465 kWh (compared to ventilation without heat recovery) and free cooling of 1052 kWh (cooling with respect to inside temperature) during a full year. The observed seasonal performance factor SPF is 17 for the avoided heating and 8 for the free cooling. The thermal efficiency based on supply air temperature is observed to be as high as 91% for a slightly unbalanced air flow. When this is mathematically corrected, thermal efficiency would have been 97% for a perfect balance between supply and return air flow.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Long term monitoring of residential heat recovery ventilation with ground heat exchange.
- Identifiant de la fiche : 30008998
- Langues : Anglais
- Sujet : Environnement
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
-
Indoor air quality in sustainable, energy effic...
- Auteurs : PERSILY A. K., EMMERICH S. J.
- Date : 02/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 1-2
Voir la fiche
-
Towards higher energy efficiency of residential...
- Auteurs : FREI B., HUBER H.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Thermal radiation heat transfer: including wave...
- Auteurs : ZEVENHOVEN R., FÄLT M., GOMES L. P.
- Date : 12/2014
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 86
Voir la fiche
-
Mediterranean Congress of HVAC (Climamed 2017)....
- Organisateur : AiCARR, AICVF, TTMD
- Date : 05/2017
- Langues : Anglais
- Formats : PDF
Voir la fiche
-
Can plants save money: a look at the Biowall.
- Auteurs : RODGERS K. L., HUTZEL W. J., DANA M., et al.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 2nd International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche