Long term monitoring of residential heat recovery ventilation with ground heat exchange.
Number: pap. 397
Author(s) : CREMERS B.
Summary
The monitoring of a demand controlled heat recovery ventilation system with ground heat exchange in a zero-energy building in Groenlo, The Netherlands, revealed interesting practical insights. A healthy indoor climate can be obtained with high comfort in terms of CO2 levels and supply air temperatures. The CO2 level stays well within the comfortable range in the living room and three bed rooms (parents, child, and guests), thanks to the demand controlled ventilation system. Supply air temperatures are in the comfortable range thanks to heat recovery in combination with ground heat exchange by an earth pipe. This is shown for ambient temperatures between -8°C and +33°C. The energy efficient behaviour is proven by the avoided heating load of 3465 kWh (compared to ventilation without heat recovery) and free cooling of 1052 kWh (cooling with respect to inside temperature) during a full year. The observed seasonal performance factor SPF is 17 for the avoided heating and 8 for the free cooling. The thermal efficiency based on supply air temperature is observed to be as high as 91% for a slightly unbalanced air flow. When this is mathematically corrected, thermal efficiency would have been 97% for a perfect balance between supply and return air flow.
Available documents
Format PDF
Pages: 10 p.
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: Long term monitoring of residential heat recovery ventilation with ground heat exchange.
- Record ID : 30008998
- Languages: English
- Subject: Environment
- Source: Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Publication date: 2013/06/16
Links
See other articles from the proceedings (424)
See the conference proceedings
-
Indoor air quality in sustainable, energy effic...
- Author(s) : PERSILY A. K., EMMERICH S. J.
- Date : 2012/02
- Languages : English
- Source: HVAC&R Research - vol. 18 - n. 1-2
View record
-
Indoor air quality: insights for designing ener...
- Author(s) : OLIVIERA-FERNANDES E. de
- Date : 1994
- Languages : English
- Source: Int. J. sol. Energy - vol. 15 - n. 1-4
View record
-
Problemas de calidad del aire interior en los e...
- Author(s) : MÜLLER J., SKRZYNIOWSKA D.
- Date : 2012/09
- Languages : Spanish
- Source: Frío Calor Aire acondicionado - vol. 40 - n. 450
- Formats : PDF
View record
-
Indoor air quality problems in passive buildings.
- Author(s) : MÜLLER J., SKRZYNIOWSKA D.
- Date : 2011/08/21
- Languages : English
- Source: Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
View record
-
Mediterranean Congress of HVAC (Climamed 2017)....
- Organiser : AiCARR, AICVF, TTMD
- Date : 2017/05
- Languages : English
- Formats : PDF
View record