Résumé
Air source pump is widely used, and a capacity modulation with concentration of mixture refrigerant is a new type modulation of environment protection and energy conservation. In this paper, the state of the art of existing variable concentration devices with mixture refrigerant is presented and their types are described according to their locations in the system. The analysis results indicate that the variable concentration device should be at the outlet of liquid refrigerant in order to change concentration of mixture refrigerant in air source heat pump. Moreover, a rectification section is more effective to change concentration than a gas-liquid separator or liquid reservoir, and the middle throttling apparatus should be an electronic regulation device other than a capillary tube. The improvement and application of variable concentration devices in air source heat pumps are also discussed.
Documents disponibles
Format PDF
Pages : 35-40
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 2008-1370
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 28 - n. 118
- Date d'édition : 12/2007
Liens
Voir d'autres articles du même numéro (5)
Voir la source
Indexation
-
Thèmes :
Techniques des pompes à chaleur;
Mélanges - Mots-clés : Rectification; Air-air; Pompe à chaleur; Mélange binaire; Frigorigène; Concentration; Composant
-
RECHERCHE DU SORBANT OPTIMAL POUR LES POMPES A ...
- Auteurs : JEDAY M. R., LE GOFF P.
- Date : 1988
- Langues : Français
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 11 - n. 1
- Formats : PDF
Voir la fiche
-
UN PROBLEME DE COMMANDE OPTIMALE PAR UNE POMPE ...
- Auteurs : ZINO I. E., SULIN A. B.
- Date : 1986
- Langues : Russe
- Source : Z. teh. Fiz. - vol. 56 - n. 11
Voir la fiche
-
Performance enhancement of some alternatives to...
- Auteurs : SAMI S. M., DESJARDINS D. E.
- Date : 25/03/2000
- Langues : Anglais
- Source : Int. J. Energy Res. - vol. 24 - n. 4
Voir la fiche
-
Prestaciones de bombas de calor cargadas con me...
- Auteurs : KANG D. G., PARK K. J., JUNG D.
- Date : 05/2010
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 425
- Formats : PDF
Voir la fiche
-
A novel absorption-cycle heat pump. 1. Refriger...
- Auteurs : WHITE S. D., O'NEILL B. K.
- Date : 1994
- Langues : Anglais
- Source : Appl. Energy - vol. 47 - n. 4
Voir la fiche