Système de chauffage, de ventilation et conditionnement d'air efficace sur le plan énergétique pour une salle d'opération inoccupée grâce à la réduction du renouvellement d'air.
Energy efficient HVAC system by reducing air change rate for an unoccupied operating room.
Numéro : pap. 627
Auteurs : WANG F. J., LEE M. J., LAI C. M., et al.
Résumé
The HVAC systems for operating rooms are energy-intensive and sophisticated in that they operate 24 hours per day year-round and use large amounts of fresh air to deal with infectious problems and to dilute microorganisms. However, little quantitative information has been investigated about the trade-off between energy efficient HVAC system and indoor environment quality especially when the operating room is not occupied. The objective of this study is to present the field measurement approach on performance evaluation of the HVAC systems for an unoccupied operating room. Variable air volume terminal boxes were conducted to verify the compromise of energy-saving potential and indoor environment parameters including particle counts, microbial counts, pressurization, temperature and humidity. Field measurements of a full-scale operating room have been carried out at a district hospital in Taiwan. Numerical simulation has been applied to evaluate the air flow distribution and concentration contours while conducting the reducing air change rate (ACH) approach in the unoccupied operating room. The results reveal that it is feasible to achieve satisfactory indoor environment by reducing the ACH in the unoccupied operating room. Optimal ACH for the variable air volume terminal boxes could be obtained through compromising of indoor environment quality control and energy consumption as well. It will stimulate a more robust investigation of infection-controlled, energy-efficient and environment comfortable HVAC systems specifically tailored for unoccupied operating rooms.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Energy efficient HVAC system by reducing air change rate for an unoccupied operating room.
- Identifiant de la fiche : 30009420
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Date d'édition : 16/06/2013
Liens
Voir d'autres communications du même compte rendu (424)
Voir le compte rendu de la conférence
Indexation
-
Traitement d’air des blocs opératoires et énerg...
- Auteurs : WOOG F., BRESIN S.
- Date : 03/2012
- Langues : Français
- Source : Salles propres - n. 79
Voir la fiche
-
The energy evaluation of the decentralized or c...
- Auteurs : POROWSKI M.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Analyse des risques : mesurage régulier des cla...
- Auteurs : GAUTIER C.
- Date : 04/2009
- Langues : Français
- Source : Salles propres - n. 61
Voir la fiche
-
Study on contaminant control in bone marrow tra...
- Auteurs : WU Y. L., CHAO H. H., LIN R. Y.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
Le conditionnement d'air dans des salles d'opér...
- Auteurs : RIVA F.
- Date : 1991
- Langues : Italien
- Source : Install. ital. - vol. 42 - n. 6
Voir la fiche