Recommandé par l'IIF / Document IIF
Système de conditionnement d’air split air-air avec une charge minimale de propane.
Air-air split AC with minimum charge of propane.
Numéro : 0010
Auteurs : ANDERSON K., LUNDAHL G., GRANRYD E.
Résumé
This paper describes technology for an environmentally friendly split type air conditioner, characterized by using safe amounts of propane as refrigerant. The objective was to demonstrate a system, using less than 150 g of propane, providing minimum 3.5 kW cooling capacity with a COP2≥3.5 at air flows that allow acceptable noise levels.
The condenser and evaporator were of standard microchannel type. The evaporator headers were rebuilt to reduce charge and different techniques were tested for even refrigerant distribution. A DC-motor scroll compressor for AC in electric vehicles was used, characterized by small internal volumes, small oil charge and wide capacity range (800-8500 rpm). The system also included a specially built minichannel liquid/suction line heat exchanger and a standard electronic expansion valve. The connection lines in-between the indoor and outdoor unit were 6 m long.
The project target was reached with a charge of 143 g propane.
Documents disponibles
Format PDF
Pages : 12 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Air-air split AC with minimum charge of propane.
- Identifiant de la fiche : 30029655
- Langues : Anglais
- Sujet : Technologie
- Source : 15th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2022). Proceedings. Trondheim, Norway, June 13-15th 2022.
- Date d'édition : 13/06/2022
- DOI : http://dx.doi.org/10.18462/iir.gl2022.0010
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres communications du même compte rendu (169)
Voir le compte rendu de la conférence
-
Use of peripheral fins for R-290 charge reducti...
- Auteurs : RIBEIRO G. B., BARBOSA J. Jr
- Date : 10/2019
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 106
- Formats : PDF
Voir la fiche
-
R290 leakage hazards assessment of a 1 HP split...
- Auteurs : NING Q., HE G., SUN W., FAN M., LI X., HONG Z.
- Date : 07/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 139
- Formats : PDF
Voir la fiche
-
Indoor leakage test for safety of R-290 split t...
- Auteurs : LI T.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
Assessment of factors affecting R290 concentrat...
- Auteurs : COLBOURNE D., SUEN K. O.
- Date : 18/06/2018
- Langues : Anglais
- Source : 13th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2018). Proceedings. Valencia, Spain, June 18-20th 2018.
- Formats : PDF
Voir la fiche
-
Performance comparison of three refrigerants in...
- Auteurs : WAN H., CAO T., HWANG Y., CHANG S. D.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche