Système de transport de chaleur de la prochaine génération pour un centre de données utilisant le CO2 comme frigorigène — 2e rapport : circulation naturelle.
Next-generation heat transportation system for data center using CO2 as refrigerant —2nd report: natural circulation.
Numéro : pap. n. 145
Auteurs : JEONG J., SAITO K., UDAGAWA Y.
Résumé
In recent years, information and communications technologies (ICT) have become widely used. With this change, the performance of IT devices, such as servers and routers for data centres, has advanced, and their density volume has increased greatly. Consequently, the heat generated by ICT facilities, which accounts for more than 30% of the total electricity consumed by data centres, has also increased greatly. Therefore, we must develop efficient cooling technologies for data centres. To achieve efficient data centre air conditioning, we constructed a CO2 heat transportation system of the server spot-cooling type based on typical data centre air conditioning methods. Saito et al. (2012) investigated the operation characteristics of the forced circulation system that was operated between blade server racks, with CO2 as a working fluid. This paper discussed the operation system that saves energy by eliminating the need for a power source, such as a pump or compressor, to drive the circulation. Hence, we investigated the systems performance and characteristics under CO2 natural circulation using simulations and experiments. The results showed that the experimental and simulated tendencies by the server rack exhausted air temperature and server rack air volume flow rate were consistent, although slight differences appeared. We determined that the heat transportation performance factor has a maximum point at a low heat transfer rate and cooling air outlet temperature because the fan power required for air volume flow increases with increasing air volume flow rate.
Documents disponibles
Format PDF
Pages : 7 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Next-generation heat transportation system for data center using CO2 as refrigerant —2nd report: natural circulation.
- Identifiant de la fiche : 30004274
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Date d'édition : 25/06/2012
Liens
Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence
Indexation
-
Next-generation heat transportation system for ...
- Auteurs : SAITO K., JEONG J., UDAGAWA Y.
- Date : 25/06/2012
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Formats : PDF
Voir la fiche
-
An experimental investigation of an R744 two-ph...
- Auteurs : TONG Z., DING T., LI Z., et al.
- Date : 05/11/2015
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 90
Voir la fiche
-
Experimental and numerical investigation on a C...
- Auteurs : ZHANG H., SHI Z., LIU K., et al.
- Date : 25/01/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 111
Voir la fiche
-
CO2 as a refrigerant for cooling of data-center...
- Auteurs : SOLEMDAL Y., EIKEVIK T. M., TOLSTOREBROV I., et al.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
CONDITIONNEMENT D'AIR DE LOCAUX SPECIAUX.
- Auteurs : WEEL W. van der
- Date : 1985
- Langues : Néerlandais
- Source : Verwarm. Vent. - vol. 42 - n. 2
Voir la fiche