Résumé
This paper describes the operating experiences associated with a medium size CO2/NH3 cascade refrigeration system installed in a commercial food processing facility in South East Queensland, Australia. The operating experiences referred to are within the time period from commencement of commercial operation in November 2006 to early 2008. The large number of CO2 compressor discharge pipe failures and how these problems were remedied are described. The freezer store serviced by the CO2 loop is provided with a penthouse type evaporator with two finned air cooling coils. The dry expansion feed to these coils, the electronic expansion valve control algorithm and the coil performance prediction are described. The CO2 compressor suction superheat recommended by the manufacturer is compared with the experiences from practical plant operation and possible CO2 system simplifications are described. An alternative CO2 receiver location and how this would impact on potential CO2 losses during power outages is detailed.
Documents disponibles
Format PDF
Pages : 2008-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Cascade refrigeration system employing NH3 and CO2: operating experiences from a food processing plant.
- Identifiant de la fiche : 2009-0566
- Langues : Anglais
- Sujet : Technologie
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Date d'édition : 07/09/2008
Liens
Voir d'autres communications du même compte rendu (132)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes à compression;
Evaporateurs, condenseurs et autres échangeurs thermiques;
Ammoniac;
Circulation du fluide : tuyauterie, régulation, automatisme, sécurité;
CO2 - Mots-clés : Technologie; Système frigorifique; Application alimentaire; Tuyauterie; Conception; Régulation; Ammoniac; Système en cascade; Frigorigène; Échangeur de chaleur; CO2
-
Scambiatori di calore ad aria per cicli frigori...
- Auteurs : LOZZA G., PERFETTI C.
- Date : 2003
- Langues : Italien
- Source : Industria & Formazione - vol. 27 - n. 274
Voir la fiche
-
Charge minimization of refrigerant systems usin...
- Auteurs : DOORNBOS G. J., VERMEEREN R. J. F.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Refrigerant charge reduction: exchanger technol...
- Auteurs : LISSANDRE J. P.
- Date : 06/04/2009
- Langues : Anglais
- Source : RCR 2009. 1st IIR Workshop on Refrigerant Charge Reduction in Refrigerating Systems.
- Formats : PDF
Voir la fiche
-
Introduction d'un système frigorifique en casca...
- Auteurs : YABUSHITA T.
- Date : 02/2005
- Langues : Japonais
- Source : Refrigeration - vol. 80 - n. 928
Voir la fiche
-
Test of an open reciprocating compressor operat...
- Auteurs : BRAENDGAARD T.
- Date : 03/09/1996
- Langues : Anglais
- Source : Applications for Natural Refrigerants
- Formats : PDF
Voir la fiche