Système réversible de chauffage, de ventilation et de conditionnement d'air pour les trains.
Unidad reversible de aire HVAC para trenes públicos.
Auteurs : HAFNER A., FÖRSTERLING S., BO ANDREASSEN H. E., et al.
Type d'article : Article
Résumé
A possible system for heating and cooling of a train compartment has been modelled and simulated. This system is a turntable HVAC unit developed at SINTEF, which is reversing the airflows to provide either cooling or heating. It has two gascoolers and two evaporators for separate treatment of ambient and recirculated air. The entire HVAC unit is rotated 180° to switch from heating to cooling mode. Carbon dioxide, CO2 (R744) is a sustainable working fluid for such systems. R744 systems have a large potential for expansion work recovery. If unrealized, this results in large throttling losses at high ambient temperature operation. An ejector is therefore added to the heat pumping circuit. In order to simulate the steady state and transient operation mode of the turntable HVAC unit a simulation model was built using Modelica as programming language. The refrigerant cycle including the ejector system was modelled based on the TIL-Library. Main focus of this study is the investigation of the ejector system performance at different ambient conditions and required heat and cooling capacities. Simulations were performed for the air reversing HVAC unit based on the heating and cooling demand when operated in 5 European cities representing a wide climatic diversity. The COP for cooling mode ranges from 2 to 4.5, depending on load and occupancy rate. The COP in heating mode ranges from 6 to 2. The efficiency decreases with reduced occupancy rate. The annual energy saving potential are calculated for all the 5 cities of the study, compared to current HVAC systems for trains.
Documents disponibles
Format PDF
Pages : 34-44 (9 p.)
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Unidad reversible de aire HVAC para trenes públicos.
- Identifiant de la fiche : 30004947
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 40
- Date d'édition : 07/2012
Liens
- Voir les traductions : Air reversing HVAC unit for public trains.
Voir d'autres articles du même numéro (4)
Voir la source
-
Air reversing HVAC unit for public trains.
- Auteurs : HAFNER A., FÖRSTERLING S., BO ANDREASSEN H. E., et al.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche
-
Performance of high pressure air cycle in compa...
- Auteurs : KRUSE H., RÜSSMANN H., JAKOBS R.
- Date : 17/07/2006
- Langues : Anglais
- Source : 2006 Purdue Conferences. 18th International Compressor Engineering Conference at Purdue & 11th International Refrigeration and Air-Conditioning Conference at Purdue [CD-ROM].
- Formats : PDF
Voir la fiche
-
Betriebserfahrungen mit einer Kaltluftklimaanla...
- Auteurs : BOECK L., KESKE K., KÖHLER W.
- Date : 02/2002
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 38 - n. 2
Voir la fiche
-
Investigation of a two-phase flow ejector in a ...
- Auteurs : LIU F., GROLL E.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
R744 train HVAC unit.
- Auteurs : HAFNER A., BANASIAK K., BOECK L.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche