Résumé
This paper describes use of low-temperature (LT) and medium-temperature (MT) CO2 refrigeration systems in supermarket applications. The Linde Refrigeration Company refrigeration plant employs a cascade heat exchanger where the waste heat of the LT CO2 system is transferred to a conventional MT HFC system typically operated with R404A or R134a. The cascade arrangement limits the high-side pressure of the LT CO2 system to a maximum of 40 bars. Due to the high density of the CO2 suction gas, very small dimensions for compressors and the piping system are achieved. Excellent boiling heat transfer properties lead to higher CO2 evaporating temperatures, thereby compensating for the energy penalty imposed by the cascade heat exchanger. Based on the positive experience with LT systems, efforts were undertaken to develop a transcritical CO2 system for MT application and thus affect an all-CO2 refrigeration system. While many standard components were possible for the LT-system, original designs were needed for the MT-system due to high-side system pressures of up to 120 bars. This presented significant design challenges, particularly with regard to the compressors, gas coolers, and high-side expansion valves. Experience to date suggests that these systems are potentially viable alternatives to HFC-based supermarket refrigeration systems.
Documents disponibles
Format PDF
Pages : 9 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : CO2-DX systems for medium-and low-temperature refrigeration in supermarket applications.
- Identifiant de la fiche : 30016800
- Langues : Anglais
- Sujet : Alternatives aux HFC
- Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Date d'édition : 21/07/2007
Liens
Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Supermarchés, meubles de vente - Mots-clés : Système frigorifique; Basse température; Détente directe; Conception; Supermarché; Substitut; HFC; Cycle transcritique; CO2
-
Performance evaluation and control optimization...
- Auteurs : GE Y. T., TASSOU S. A.
- Date : 29/03/2010
- Langues : Anglais
- Source : 1st IIR International Conference on Sustainability and the Cold Chain
- Formats : PDF
Voir la fiche
-
Supermarket application. CO2 all-in-one transcr...
- Auteurs : SHEEHAN J., MAZZOLA D., ORLANDI M.
- Date : 21/08/2016
- Langues : Anglais
- Source : 12th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2016). Proceedings. Édimbourg, United Kingdom, August 21st-24th 2016.
- Formats : PDF
Voir la fiche
-
Evaluation of a transcritical CO2 supermarket r...
- Auteurs : SHARMA V., FRICKE B., BANSAL P., et al.
- Date : 16/04/2015
- Langues : Anglais
- Source : 6th Conference on Ammonia and CO2 Refrigeration Technology. Proceedings: Ohrid, North Macedonia, April 16-18, 2015.
- Formats : PDF
Voir la fiche
-
Eine neuentwickelte CO2-kälteanlage für den Nor...
- Auteurs : HEINBOKEL B., GERNEMANN A.
- Date : 16/11/2005
- Langues : Allemand
- Source : DKV-Tagungsbericht 2005, Würzburg./ 2005 Proceedings of the DKV Conference, Würzburg.
Voir la fiche
-
Reducing the carbon footprint of commercial ref...
- Auteurs : FRICKE B., ABDELAZIZ O., VINEYARD E.
- Date : 02/04/2013
- Langues : Anglais
- Source : 2nd IIR International Conference on Sustainability and the Cold Chain. Proceedings: Paris, France, April 2-4, 2013.
- Formats : PDF
Voir la fiche