Document IIF

Technologie empêchant l'encrassement des condenseurs à eau à bandes torsadées "auto-rotatives" entraînées à l'entrée par des paliers en spirale.

Fouling preventing technology for water-cooled condensers with self-rotating twisted strips driven by spiral inlet bearings.

Auteurs : YU T. L., YU X. M., LIU Y. P., et al.

Résumé

The loss caused by water-cooled condenser fouling in registration units is estimated to be over 0.3 billion USD per year in China. The self-rotating twisted plastic strip is a good technology to eliminate water fouling and to enhance heat transfer at the same time. But its self-rotating force moment is usually not enough to work in tough situations. So, an improved technology with inlet spiral water flow is developed. Both theoretical analyses and experiments show that the design of water directing strips with small spiral angle and inside tubes with a large diameter on the inlet bearing can effectively increase the moment. For example, type-2030 bearing can make the driving wheel get an additional moment, which is equivalent to 335% moment of a 2-m twisted strip. This new technology is very reliable and works well in most water-cooled systems.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Fouling preventing technology for water-cooled condensers with self-rotating twisted strips driven by spiral inlet bearings.
  • Identifiant de la fiche : 2004-2790
  • Langues : Anglais
  • Source : 21st IIR International Congress of Refrigeration: Serving the Needs of Mankind.
  • Date d'édition : 17/08/2003

Liens


Voir d'autres communications du même compte rendu (398)
Voir le compte rendu de la conférence