Document IIF

Température du point triple de cinq frigorigènes fluorés dérivés du propane.

Triple point temperature for five fluorinated propane derivatives refrigerants.

Numéro : pap. ID: 473

Auteurs : DI NICOLA G., DI NICOLA C., GIULIANI G., et al.

Résumé

A recently developed Solid-Liquid Equilibria (SLE) apparatus was used to measure the triple point temperature of five propane derivatives alternative refrigerants, namely 1,1,1,2,3,3,3-hepta-fluoropropane (R227ea), 1,1,2,3,3,3-Hexafluoropropane (R236ea), 1,1,1,3,3-Pentafluoropropane (R245fa), 1,1,2,2,3- Pentafluoropropane (R245ca), 1,1,1,3,3,3-hexafluoropropane (R236fa). The experimental set-up, that was recently adopted for the SLE estimation of CO2+HFCs binary systems, comprises a measuring cell and a system for drawing the liquid nitrogen directly from its insulated tank with the aid of compressed air: the carrier fluid circulating in the circuit is thus the refrigerant fluid itself. The measurements were performed both in the heating and in the cooling mode. In order to confirm the functional efficiency and fine adjustment of the apparatus, the already available triple point literature data for other HFCs were also compared with the ones measured by the present set-up. The measured triple-point data revealed some discrepancy with the literature.

Documents disponibles

Format PDF

Pages : 6 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Triple point temperature for five fluorinated propane derivatives refrigerants.
  • Identifiant de la fiche : 30003196
  • Langues : Anglais
  • Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
  • Date d'édition : 21/08/2011

Liens


Voir d'autres communications du même compte rendu (569)
Voir le compte rendu de la conférence