Document IIF

Transfert de chaleur et pertes visqueuses dans les régénérateurs passifs à micro-canaux. 2. Extraction des paramètres.

Heat transfer and viscous losses in microchannel passive regenerators. 2. Parameter extraction.

Résumé

The essential component of active magnetic refrigeration (AMR) technology is the regenerator. In order to characterize a given regenerator matrix numerous transport quantities must be determined experimentally. In particular, the pressure drop and the heat transfer coefficient is needed for design optimization and modelling purposes of AMR systems. In this paper a novel method is outlined for the extraction of those transport coefficients given experimental data. The experimentally obtained values are compared to theoretical calculations. See also this issue of the Bulletin, reference 2011-0192.

Documents disponibles

Format PDF

Pages : 2010-4

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Heat transfer and viscous losses in microchannel passive regenerators. 2. Parameter extraction.
  • Identifiant de la fiche : 2011-0193
  • Langues : Anglais
  • Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
  • Date d'édition : 23/08/2010

Liens


Voir d'autres communications du même compte rendu (54)
Voir le compte rendu de la conférence