Document IIF
Transfert de chaleur et pertes visqueuses dans les régénérateurs passifs à micro-canaux. 2. Extraction des paramètres.
Heat transfer and viscous losses in microchannel passive regenerators. 2. Parameter extraction.
Auteurs : SCHOPFER S., TURA A., ROWE A.
Résumé
The essential component of active magnetic refrigeration (AMR) technology is the regenerator. In order to characterize a given regenerator matrix numerous transport quantities must be determined experimentally. In particular, the pressure drop and the heat transfer coefficient is needed for design optimization and modelling purposes of AMR systems. In this paper a novel method is outlined for the extraction of those transport coefficients given experimental data. The experimentally obtained values are compared to theoretical calculations. See also this issue of the Bulletin, reference 2011-0192.
Documents disponibles
Format PDF
Pages : 2010-4
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Heat transfer and viscous losses in microchannel passive regenerators. 2. Parameter extraction.
- Identifiant de la fiche : 2011-0193
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Date d'édition : 23/08/2010
Liens
- Voir aussi : Heat transfer and viscous losses in micro-channel passive regenerators. 1. Apparatus and experimental results.
Voir d'autres communications du même compte rendu (54)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Mesures thermodynamiques;
Transfert de chaleur;
Applications domestiques (réfrigérateurs, congélateurs);
Froid calorique (froid magnétocalorique, électrocalorique, élastocalorique et barocalorique) - Mots-clés : Géometrie; Microcanal; Réfrigerateur magnétique; Froid magnétocalorique; Transfert de chaleur; Régénérateur; Perte; Optimisation; Modélisation; Experimentation; Chute de pression
-
Design concepts for a continuously rotating act...
- Auteurs : BAHL C. R. H., ENGELBRECHT K., BJØRK R., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche
-
Numerical analysis of an active magnetic regene...
- Auteurs : ROUDAUT J., KEDOUS-LEBOUC A., YONNET J. P., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche
-
Experimental and numerical study on rotary acti...
- Auteurs : OUYANG G., HOU P. X., WU J. H., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche
-
The cooling capacity of hybrid regenerative cycle.
- Auteurs : LU Y. F., ZHI T., GONG Y. Y., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche
-
An analysis and calculation of regenerative pro...
- Auteurs : GONG Y. Y., ZHI T., LU Y. F., et al.
- Date : 23/08/2010
- Langues : Anglais
- Source : 4th International Conference on Magnetic Refrigeration at Room Temperature (Thermag IV). Proceedings: Baotou, China, August 23-27, 2010.
- Formats : PDF
Voir la fiche