Résumé
It is crucial to enhance the ejector capacity to widen its application in industry. A novel ejector with a bypass installed in the low pressure district is proposed to enhance the ejector capacity. The results show that there is an optimal position for the maximum entrainment ratio, which corresponds to the lowest pressure around the second shock position. When the ejector operates at design conditions (the primary/induced/back pressures are 0.3/0.02/0.08?MPa), the optimal length ratio is about 1.1. Then, the ejector performance with the optimal bypass is investigated under different operational parameters. It is found that the novel ejector has relatively high entrainment ratio and low critical back pressure compared to the ejector without bypass under the design condition. When the primary pressure is bigger than a certain value, the entrainment ratio would always improve as the primary or induced pressures increase.
Détails
- Titre original : A novel ejector with a bypass to enhance the performance.
- Identifiant de la fiche : 30017065
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
- Date d'édition : 25/01/2016
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2015.10.067
Liens
Voir d'autres articles du même numéro (72)
Voir la source
Indexation
-
Experimental investigation on ejector performan...
- Auteurs : WANG L., WANG C., HOU W., et al.
- Date : 08/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 80
- Formats : PDF
Voir la fiche
-
Experimental and numerical investigation of the...
- Auteurs : ZHU Y., JIANG P. X.
- Date : 04/2014
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 40
- Formats : PDF
Voir la fiche
-
A one dimensional model for the determination o...
- Auteurs : GARCÍA del VALLE J., SAIZ JABARDO J. M., CASTRO RUIZ F., et al.
- Date : 06/2012
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 4
- Formats : PDF
Voir la fiche
-
A 1D model to predict ejector performance at cr...
- Auteurs : CHEN W., LIU M., CHONG D., et al.
- Date : 09/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 6
- Formats : PDF
Voir la fiche
-
Development of ejector performance map for pred...
- Auteurs : HAIDER M., ELBEL S.
- Date : 08/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 128
- Formats : PDF
Voir la fiche