Un frigorigène de remplacement ininflammable, à GWP réduit, pour le HFC-134a : le DR-11.
A non-flammable, reduced GWP, HFC-134a replacement in centrifugal chillers: DR-11.
Auteurs : KONTOMARIS K., LECK T. J., HUGHES J.
Résumé
Air conditioning in large buildings is often provided by centrifugal chillers using HFC-134a. Efforts to mitigate climate change are motivating the identification of HFC replacements with low GWPs. HFO-1234yf, with a GWP(100)= 4, has been found promising as an HFC-134a replacement in centrifugal chillers (Kontomaris et al., 2010). However, HFO-1234yf is marginally (ASHRAE 2L) flammable. A new non-flammable developmental refrigerant, DR-11, with a GWP(100) lower than 600, was evaluated as an HFC-134a replacement in centrifugal chillers. Given the minimal refrigerant emissions from chillers and its higher predicted energy efficiency, DR-11 could enable solutions with comparable or even lower total global warming impact than HFO-1234yf despite its higher GWP. Moreover, the higher predicted DR-11 refrigeration capacity and the lack of DR-11 flammability may allow more cost-effective solutions than HFO-1234yf that can be adopted without any delays for safety code revisions. Flexible climate change regulations would allow acceptance of refrigerants with optimum performance, flammability and GWP trade-offs.
Documents disponibles
Format PDF
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : A non-flammable, reduced GWP, HFC-134a replacement in centrifugal chillers: DR-11.
- Identifiant de la fiche : 2010-2002
- Langues : Anglais
- Date d'édition : 12/07/2010
- Source : Source : Proc. 2010 int. Refrig. Air Cond. Conf., Purdue Univ.
n. 2142; 8 p.; fig.; tabl.; 10 ref.
Indexation
-
Thèmes :
Systèmes à compression;
HFC;
Refroidisseurs d'eau - Mots-clés : R134a; Comparaison; Bâtiment commercial; Refroidisseur; Substitut; Secteur tertiaire; Inflammabilité; GWP; Grand volume; Efficacité énergétique; Effet de serre; Frigorigène; Confort thermique; Conditionnement d'air; Eau glacée; Compresseur centrifuge
-
The part-load efficiency benefit of oil-free, h...
- Auteurs : ALVARES J.
- Date : 12/07/2010
- Langues : Anglais
- Source : 2010 Purdue Conferences. 20th International Compressor Engineering Conference at Purdue.
- Formats : PDF
Voir la fiche
-
How to minimize TEWI: case history with oil fre...
- Auteurs : FADIGA F.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
How to minimize TEWI: case history with oil fre...
- Auteurs : FADIGA F.
- Date : 09/2018
- Langues : Anglais
- Source : 1st IIR international conference on the application of HFO refrigerants, Birmingham, September 2-5 2018.
- Formats : PDF
Voir la fiche
-
Energy optimization of an in-service building c...
- Auteurs : VU H. D., KEATING B. D., ALLEYNE A. G., et al.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Global warming impact of low GWP chiller refrig...
- Auteurs : KONTOMARIS K.
- Date : 21/08/2011
- Langues : Anglais
- Source : Proceedings of the 23rd IIR International Congress of Refrigeration: Prague, Czech Republic, August 21-26, 2011. Overarching theme: Refrigeration for Sustainable Development.
- Formats : PDF
Voir la fiche