Document IIF

Un refroidisseur par rayonnement appliqué dans un système frigorifique étagé.

A radiant cooler applied in compound-refrigerating system.

Résumé

A two stage radiant cooler applied in a compound-refrigerating system (CRS) was developed. The CRS radiant cooler could provide 8.5 W cooling power at the temperature of 195 K and the refrigeration capacity of the cooler met the requirement of the compound-refrigerating system. In this paper, the processes of structure selection, thermal design, optimization design and thermal-vacuum test were described in detail. Monte Carlo method was applied in the calculation of radiant interchange factor and the calculation error was less than 0.4%. Through optimization design, the working performance of the optimized radiant cooler almost kept no change, though the structure dimensions decreased greatly. The optimization design method based on the non-scale heat theory and numerical calculation was proved to be effective.

Documents disponibles

Format PDF

Pages : ICR07-A1-1229

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : A radiant cooler applied in compound-refrigerating system.
  • Identifiant de la fiche : 2007-2397
  • Langues : Anglais
  • Source : ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
  • Date d'édition : 21/08/2007

Liens


Voir d'autres communications du même compte rendu (839)
Voir le compte rendu de la conférence