IIR document
A radiant cooler applied in compound-refrigerating system.
Author(s) : WANG X. J., PAN Y. P., ZHU J. B.
Summary
A two stage radiant cooler applied in a compound-refrigerating system (CRS) was developed. The CRS radiant cooler could provide 8.5 W cooling power at the temperature of 195 K and the refrigeration capacity of the cooler met the requirement of the compound-refrigerating system. In this paper, the processes of structure selection, thermal design, optimization design and thermal-vacuum test were described in detail. Monte Carlo method was applied in the calculation of radiant interchange factor and the calculation error was less than 0.4%. Through optimization design, the working performance of the optimized radiant cooler almost kept no change, though the structure dimensions decreased greatly. The optimization design method based on the non-scale heat theory and numerical calculation was proved to be effective.
Available documents
Format PDF
Pages: ICR07-A1-1229
Available
Public price
20 €
Member price*
Free
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: A radiant cooler applied in compound-refrigerating system.
- Record ID : 2007-2397
- Languages: English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Publication date: 2007/08/21
Links
See other articles from the proceedings (839)
See the conference proceedings
Indexing
- Themes: Small-scale cryogenic applications, cryocoolers
- Keywords: Radiation; Design; Gas cooler; Stirling; Expérimentation; Cryocooler
-
Experimental study on high capacity free piston...
- Author(s) : CHEN X., ZHANG H., WU Y. N., et al.
- Date : 2007/08/21
- Languages : English
- Source: ICR 2007. Refrigeration Creates the Future. Proceedings of the 22nd IIR International Congress of Refrigeration.
- Formats : PDF
View record
-
Study of performance characteristics of a 40 W/...
- Author(s) : CHEN X., WU W. D., ZHANG H., et al.
- Date : 2008/04/05
- Languages : English
- Source: Cryogenics and refrigeration. Proceedings of ICCR'2008.
View record
-
Stirling-type pulse tube cryocooler with 1 kW o...
- Author(s) : POTRATZ S. A., ABBOTT T. D., JOHNSON M. C., et al.
- Date : 2007/07/16
- Languages : English
View record
-
Development of a 300-W class Stirling cooler fo...
- Author(s) : SEKIYA H., OKAMOTO I., NAKAZAKI I., et al.
- Date : 2000/07/25
- Languages : English
- Source: Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
- Formats : PDF
View record
-
Wärmestromschalter für Kryo-Weltraumanwendungen.
- Author(s) : KAISER G., BINNEBERG A.
- Date : 1999/11/17
- Languages : German
- Source: DKV-Tagungsbericht 26. 1999, Berlin.
View record