Une étude expérimentale de l'évaluation de la performance d'un système à pompe à chaleur transcritique au CO2 sous des conditions de charges en frigorigène variables.

Un estudio experimental sobre la evaluación del rendimiento de un sistema de bomba de calor con CO2 transcrítico variando la carga de refrigerante.

Auteurs : AGRAWAL N., BHATTACHARYYA S., NANDA P.

Type d'article : Article

Résumé

CO2 transcritical vapour compression systems are more susceptible with the refrigerant charge amount. This aspect becomes more important when the system operates with the capillary tube expansion valve. In this study, the performance of a prototype CO2 heat pump system was investigated under varying refrigerant charge amount employing a capillary tube as an expansion device. At a given gas cooler and evaporator inlet water temperature, charge amount sensitivity was tested. The COP of the CO2 heat pump system was reduced more significantly at undercharged conditions than at overcharged conditions. Despite increase in the charge amount, suction superheat decreases while compressor power increases.

Documents disponibles

Format PDF

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Un estudio experimental sobre la evaluación del rendimiento de un sistema de bomba de calor con CO2 transcrítico variando la carga de refrigerante.
  • Identifiant de la fiche : 30003139
  • Langues : Espagnol
  • Source : Frío Calor Aire acondicionado - vol. 39 - n. 439
  • Date d'édition : 09/2011

Liens


Voir d'autres articles du même numéro (5)
Voir la source