Résumé
As the climate changes have happened worldwide, every country is making efforts to prevent the ozone depletion and global warming. In the automotive industry, R-134a refrigerant is widely used in these days because it has zero ozone depletion potential. But global warming potential of it is high. Therefore, alternative refrigerants are needed as a replacement of R-134a. R-152a is considered as one of the alternatives due to zero ODP and low GWP. In the paper, performances of the automotive air-conditioning system using R-134a and R-152a are compared experimentally in the bench level. Experimental apparatus simulated real automotive air-conditioning system consisting of cabin room and engine room. Cooling capacity, condensing capacity, COP and power consumption characteristics of automotive air-conditioning system are evaluated by changing air velocity entering the condenser and compressor revolution speed with the optimized refrigerant charge. The performance of R-152a system was investigated by changing the thermostatic expansion valve set values. As a result of the study, R-152a refrigerant shows the possibility of an alternative refrigerant of current R-134a in the automotive air-conditioning system.
Détails
- Titre original : An experimental study on performance of automotive air-conditioning system using R-134a and R-152a refrigerants.
- Identifiant de la fiche : 2007-0835
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
- Date d'édition : 21/05/2006
Liens
Voir d'autres communications du même compte rendu (161)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
HFC;
Conditionnement d'air mobile - Mots-clés : R134a; Comparaison; Automobile; R152a; Performance; Experimentation; Frigorigène; Conditionnement d'air
-
The performance of refrigerant R152a in an auto...
- Auteurs : SHIN J. S., PARK W. G., KIM M. H.
- Date : 21/11/2005
- Langues : Anglais
- Source : ICERD-3. Third International Conference on Energy Research and Development [2 volumes + CD-ROM].
Voir la fiche
-
State of the art review of alternative refriger...
- Auteurs : BANDARRA FILHO E. P., MENDOZA O. S. H.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche
-
Estado del arte de refrigerantes alternativos c...
- Auteurs : BANDARRA FILHO E. P., MENDOZA O. S. H.
- Date : 06/2011
- Langues : Espagnol
- Source : Frío Calor Aire acondicionado - vol. 39 - n. 437
- Formats : PDF
Voir la fiche
-
Comparison of automotive air-conditioning syste...
- Auteurs : PREISSNER M., CUTLER B., SINGANAMALLA S., et al.
- Date : 25/07/2000
- Langues : Anglais
- Source : Final proceedings of the 4th IIR-Gustav Lorentzen Conference on Natural Working Fluids at Purdue.
- Formats : PDF
Voir la fiche
-
R152a with secondary loop option: the perspecti...
- Auteurs : MONFORTE R.
- Date : 22/11/2007
- Langues : Anglais
- Source : DKV-Tagungsbericht 2007, Hannover.
Voir la fiche