Résumé
The thermal performance capacity of a wet cooling tower is dominated by weather conditions, particularly ambient wet-bulb temperature. In this paper, the tower performance was predicted by a simplified model which was characterized by specification of a mass evaporation rate equation. The purpose of this study was to present a calculation that was accurate and simple to implement, and could be applied to evaluate acceptance tests for new towers, to monitor changes in tower performance as an aid in planning maintenance, and to predict tower performance under changed operating conditions. The results were validated and showed good agreement with experimental measurements. The results were also presented in simple formats that were easy to use and understand. These allowed reduction of test data and comparison of test results to design data. The method held a practical advantage for predicted tower thermal performance capability to which it was best suited when both flow rate and temperature of inlet water were near design conditions since it required neither the measurement of air flow rate nor the calculation of tower characteristic (hmassA/L). The expected results of this study will make it possible to incorporate cooling tower design and simulation to evaluate and optimize the thermal performance of power plants for example. [Reprinted with permission from Elsevier. Copyright, 2012].
Détails
- Titre original : A simplified method on thermal performance capacity evaluation of counter flow cooling tower.
- Identifiant de la fiche : 30003815
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 38
- Date d'édition : 05/2012
- DOI : http://dx.doi.org/10.1016/j.applthermaleng.2012.01.025
Liens
Voir d'autres articles du même numéro (7)
Voir la source
Indexation
-
Thermal and chemical analysis of fouling phenom...
- Auteurs : WU X., CREMASCHI L.
- Date : 16/07/2012
- Langues : Anglais
- Source : 2012 Purdue Conferences. 14th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Influence of non-uniform layout fillings on the...
- Auteurs : GAO M., ZHANG L., WANG N. N., et al.
- Date : 25/01/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 93
Voir la fiche
-
An improved constrained inverse optimization me...
- Auteurs : SINGH K., DAS R.
- Date : 05/03/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 114
Voir la fiche
-
Review of fractal heat exchangers.
- Auteurs : HUANG Z. W., HWANG Y. H., AUTE V., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 16th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Numerical analysis of solar enhanced natural dr...
- Auteurs : ZHOU Z., GONG H.
- Date : 05/02/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 94
Voir la fiche