Document IIF
Validation expérimentale d'un éjecteur prototype conçu pour réduire les pertes de laminage lors du fonctionnement d'un système au R-744 transcritique.
Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R-744 system operation.
Résumé
This study presents experimental results obtained from a transcritical R-744 system using a refrigerant ejector. The results were compared to that of a conventional system with an expansion valve. For the test conditions considered, the cooling capacity and COP simultaneously improved by up to 8 and 7%, respectively. Experiments were analyzed to quantitatively assess the effects on system performance as a result of changes in basic ejector dimensions such as motive nozzle and diffuser sizing. Small angles of 5° yielded best results for the static pressure recovery of the high-speed two-phase flow entering the diffuser. Experiments confirmed that like in a conventional transcritical R-744 system with expansion valve, the high-side pressure control integrated into the ejector could be used to maximize the system performance. Numerical simulation results helped identifying this basic trend. Due to difficulties in the ejector throat pressure measurements, a more practical performance metric was introduced in order to quantify overall ejector efficiencies. According to this definition, the prototype ejector was able to recover up to 14.5% of the throttling losses.
Documents disponibles
Format PDF
Pages : 411-422
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental validation of a prototype ejector designed to reduce throttling losses encountered in transcritical R-744 system operation.
- Identifiant de la fiche : 2008-0569
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 3
- Date d'édition : 05/2008
Liens
Voir d'autres articles du même numéro (18)
Voir la source
-
Particular characteristics of a transcritical C...
- Auteurs : DENG J. Q., JIANG P. X., LU T., et al.
- Date : 02/2007
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 27 - n. 2-3
Voir la fiche
-
Characteristics of a two-phase ejector in carbo...
- Auteurs : AKAGI S., WANG J. F., HIHARA E.
- Date : 02/05/2005
- Langues : Anglais
- Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
Voir la fiche
-
Experimental analysis on the effect of internal...
- Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T.
- Date : 11/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 7
- Formats : PDF
Voir la fiche
-
Investigations of two-phase ejector operating w...
- Auteurs : SMIERCIEW K., BUTRYMOWICZ D., BAJ P., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Experimental investigation on the effect of mix...
- Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T., et al.
- Date : 12/04/2010
- Langues : Anglais
- Source : 9th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2010). Proceedings. Sydney, Australia, April 12-14, 2010.
- Formats : PDF
Voir la fiche