
Résumé
This paper presents experimental results obtained from a transcritical CO2 system using a refrigerant ejector instead of an expansion valve. The cooling capacity and COP simultaneously improved by up to 8 and 7%, respectively. Experiments were analyzed to quantitatively assess the effects on system performance as a result of changes in basic ejector dimensions such as motive nozzle and diffuser sizing. Small diffuser angles (5°) yielded best results. It was numerically predicted and experimentally verified that like in a conventional transcritical CO2 system, the high-side pressure control integrated into the ejector can be used to maximize the system performance. Due to difficulties in the ejector throat pressure measurements a more practical performance metric was introduced in order to quantify overall ejector efficiencies. According to this definition, the prototype ejector was able to recover up to 35% of the throttling losses.
Documents disponibles
Format PDF
Pages : 2006-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental validation and design study of a transcritical CO2 prototype ejector system.
- Identifiant de la fiche : 2007-1549
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Date d'édition : 29/05/2006
Liens
Voir d'autres communications du même compte rendu (111)
Voir le compte rendu de la conférence
-
Analysis of an ejector expansion device in a tr...
- Auteurs : LI D. Q., GROLL E. A.
- Date : 29/05/2006
- Langues : Anglais
- Source : 7th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2006). Proceedings
- Formats : PDF
Voir la fiche
-
Investigation of a two-phase flow ejector in a ...
- Auteurs : LIU F., GROLL E.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche
-
Regeneration of expansion energy by ejector in ...
- Auteurs : OZAKI Y., TAKEUCHI H., HIRATA T.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Experimental analysis on the effect of internal...
- Auteurs : NAKAGAWA M., MARASIGAN A. R., MATSUKAWA T.
- Date : 11/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 7
- Formats : PDF
Voir la fiche
-
1D analysis of CO2 sub-cooled/supercritical eje...
- Auteurs : KSAYER E. B. L., CLODIC D.
- Date : 07/09/2008
- Langues : Anglais
- Source : 8th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2008)
- Formats : PDF
Voir la fiche