Vitesse d'écoulement dans un bouilleur expérimental, déterminé par vélocimétrie avec visualisation des particules.

Flow velocities in an experimental kettle reboiler determined by particle image velocimetry.

Auteurs : BURNSIDE B. M., MILLER K. M., MCNEIL D. A., et al.

Type d'article : Article

Résumé

A particle image velocimetry autocorrelation technique was applied to produce whole field vector maps of flow beneath and to the side of a 17 row × l7 column kettle reboiler thin slice rig, boiling pentane at atmospheric pressure. The flow proved to be time dependent. The average values of the mass flow rates of the recirculating liquid were evaluated at various positions and compared to predictions of models of the flow which reproduced the measured pressure drops. The use of the results as a platform for 2D numerical modelling of the flow is emphasized.

Détails

  • Titre original : Flow velocities in an experimental kettle reboiler determined by particle image velocimetry.
  • Identifiant de la fiche : 2005-1815
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 48 - n. 5
  • Date d'édition : 02/2005

Liens


Voir d'autres articles du même numéro (5)
Voir la source