Document IIF
Amélioration de la distribution d'air régulée dans les meubles frigorifiques de vente verticaux et ouverts de supermarché.
Improvement of air distribution in refrigerated vertical open front remote supermarket display cases.
Auteurs : GRAY I., LUSCOMBE P., MCLEAN L., et al.
Type d'article : Article, Article de la RIF
Résumé
This paper presents some of the results derived from extensive experimentation on display cases for supermarkets and derives some possible improvements to augment temperature uniformity and energy performance. The effect of the perforation pattern of the rear duct on the distribution of airflow between these and the front curtain is brought out. The critical component is air infiltration across the curtain, which is governed by internal air distribution and curtain characteristics. It is observed that a 70-30 distribution of flow between the curtain and the rear duct perforations yields a performance that satisfies the standards. Further, a judicious distribution of perforations on the rear duct at various levels and across is necessary. Correlations available in the literature are useful in making a qualitative assessment of the results.
Documents disponibles
Format PDF
Pages : 902-910
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Improvement of air distribution in refrigerated vertical open front remote supermarket display cases.
- Identifiant de la fiche : 2008-1652
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 31 - n. 5
- Date d'édition : 08/2008
Liens
Voir d'autres articles du même numéro (19)
Voir la source
Indexation
- Thèmes : Supermarchés, meubles de vente
- Mots-clés : Meuble ouvert; Meuble de vente; Rideau d'air; R507; Supermarché; Experimentation; Distribution d'air
-
A correlation model of thermal entrainment fact...
- Auteurs : YU K. Z., DING G. L., CHEN T. J.
- Date : 10/2009
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 29 - n. 14-15
Voir la fiche
-
Calcul de la dynamique numérique des fluides d'...
- Auteurs : FENG X., et al.
- Date : 2001
- Langues : Chinois
- Source : Journal of Refrigeration - n. 2
- Formats : PDF
Voir la fiche
-
Numerical study on the air curtain characterist...
- Auteurs : WANG Y., QIAN S., XU J., LI L., DOU X., LI X., YAN G., YU J.
- Date : 06/2021
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 126
- Formats : PDF
Voir la fiche
-
A novel optimization strategy for the design of...
- Auteurs : CAO Z., HAN H., GU B.
- Date : 11/2011
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 31 - n. 16
Voir la fiche
-
Application of CFD in evaluation and energy-eff...
- Auteurs : CUI J., WANG S.
- Date : 10/2004
- Langues : Anglais
- Source : International Journal of thermal Sciences - vol. 43 - n. 10
Voir la fiche