Un modèle par corrélations du facteur d'entraînement thermique pour un rideau d'air dans un meuble frigorifique de vente.

A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet.

Auteurs : YU K. Z., DING G. L., CHEN T. J.

Type d'article : Article

Résumé

Thermal entrainment factor (TEF) is an important parameter to describe the cold preservation performance of a display cabinet. In order to calculate the TEF of a display cabinet rapidly and accurately, the method of establishing a correlation model based on computational fluid dynamics simulation results is presented and the correlation model of TEF for typical single and double air curtain in a vertical open display cabinet is developed in this paper. The TEF of display cabinet predicted by the correlation model gives a maximum deviation of -9.4% and a mean deviation of -0.1% compared with the published experimental data. In addition, the correlation model can be used to calculate the air curtain return temperature, showing a maximum deviation of 0.9°C and an average deviation of 0.1°C compared with the published experimental data. [Reprinted with permission from Elsevier. Copyright, 2009].

Détails

  • Titre original : A correlation model of thermal entrainment factor for air curtain in a vertical open display cabinet.
  • Identifiant de la fiche : 2009-2072
  • Langues : Anglais
  • Source : Applied Thermal Engineering - vol. 29 - n. 14-15
  • Date d'édition : 10/2009
  • DOI : http://dx.doi.org/10.1016/j.applthermaleng.2009.02.016

Liens


Voir d'autres articles du même numéro (5)
Voir la source