Document IIF
Amélioration expérimentale d'une installation frigorifique transcritique au CO2 avec un sous-refroidissement thermoélectrique.
Experimental enhancement of a CO2 transcritical refrigerating plant including thermoelectric subcooling.
Auteurs : SÁNCHEZ D., ARANGUREN P., CASI A., LLOPIS R., CABELLO R., ASTRAIN D.
Type d'article : Article de la RIF
Résumé
CO2 is an excellent natural refrigerant that can be used in almost any commercial cooling application thanks to its useful range of evaporative temperatures and excellent environmental properties. However, due to its low critical temperature, CO2 has an important issue related to the low performance of the simplest transcritical refrigeration cycle. To overcome it, the subcooling technique is a well-known method to improve the energy performance of any refrigeration cycle especially the CO2 transcritical one. The IHX is a widely used example of this method that is implemented in almost all standalone systems that use CO2 as a refrigerant. As an alternative of this element, in this work, a thermoelectric subcooling system is presented and tested in a CO2 transcritical refrigerating plant. The experimental tests have been performed at two ambient temperatures: 25 and 30 °C, maintaining a constant evaporating level at -10 °C and varying the voltage supply to thermoelectric modules and the heat rejection pressure. The results from these experimental tests revealed that the COP and the cooling capacity of the refrigerating plant can be enhanced up to 9.9% and 16.0%, respectively, operating at the optimum operating conditions. Moreover, the experimental tests corroborate the existence of an optimum voltage which maximizes the COP, and the almost linear capacity regulation easily adjustable by varying the voltage supply.
Documents disponibles
Format PDF
Pages : 178-187
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental enhancement of a CO2 transcritical refrigerating plant including thermoelectric subcooling.
- Identifiant de la fiche : 30027852
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 120
- Date d'édition : 12/2020
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2020.08.031
- Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.
Liens
Voir d'autres articles du même numéro (42)
Voir la source
Indexation
- Thèmes : CO2
- Mots-clés : CO2; R744; Cycle transcritique; Sous-refroidissement; Froid thermoélectrique; Experimentation; Comparaison; Application commerciale
-
Experimental assessment of different extraction...
- Auteurs : NEBOT-ANDRÉS L., CALLEJA-ANTA D., FOSSI C., SÁNCHEZ D., CABELLO R., LLOPIS R.
- Date : 04/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 136
- Formats : PDF
Voir la fiche
-
Experimental COP enhancement of a CO2 transcrit...
- Auteurs : ARANGUREN P., SÁNCHEZ D., CASI A., ARAIZ M., ASTRAIN D., CABELLO R.
- Date : 11/11/2020
- Langues : Espagnol
- Source : X Congreso Ibérico y VIII Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2020.
- Formats : PDF
Voir la fiche
-
Energy performance of a CO2 transcri...
- Auteurs : SÁNCHEZ D., ARANGUREN P., CASI A., CABELLO R., ASTRAIN D., ARAIZ M., LLOPIS R., CALLEJA-ANTA D., NEBOT-ANDRÉS L.
- Date : 07/12/2020
- Langues : Anglais
- Source : 14th IIR-Gustav Lorentzen Conference on Natural Refrigerants (GL2020). Proceedings. Kyoto, Japon, December 7-9th 2020.
- Formats : PDF
Voir la fiche
-
Experimental evaluation of a transcritical CO
- Auteurs : CASI A., ARANGUREN P., ARAIZ M., SÁNCHEZ D., CABELLO R., ASTRAIN D.
- Date : 09/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 141
- Formats : PDF
Voir la fiche
-
CO2 transcritical vapor compression cycle with ...
- Auteurs : SCHOENFIELD J., HWANG Y., RADERMACHER R.
- Date : 06/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 3
Voir la fiche