Analyse de performance et effet de l’échangeur de chaleur interne pour un système de conditionnement d’air automobile au R1234yf comme remplacement immédiat du R134a.
Drop-in performance analysis and effect of IHX for an automotive air conditioning system with R1234yf as a replacement of R134a.
Auteurs : DIREK M., KELESOGLU A., AKIN A.
Type d'article : Article
Résumé
This paper presents the experimental comparative performance analysis of an automotive air conditioning (AAC) system using R1234yf and R134a. For this purpose, an AAC experiment setup used for R134a was built to obtain the drop-in performance of a new refrigerant R1234yf. Among the low global warming potential (GWP) refrigerants, R1234yf was particularly chosen due to its similar thermo-physical properties with R134a. However, the system with R1234yf could not perform as efficiently as R134a can. Therefore, an internal heat exchanger (IHX) was employed to enhance the performance of the R1234yf system. After that, the performances of R1234yf and R134a were compared under various compressor speeds and air stream temperatures. The results showed that the cooling capacity and COP of the system with R1234yf were 17.1 % and 12.4 %, respectively, lower compared to the one with R134a. However, when the IHX was introduced into the system with R1234yf, the cooling capacity and COP values were significantly enhanced by 7.9 % and 4.1 %, respectively.
Documents disponibles
Format PDF
Pages : 314-319
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Drop-in performance analysis and effect of IHX for an automotive air conditioning system with R1234yf as a replacement of R134a.
- Identifiant de la fiche : 30025214
- Langues : Anglais
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 63 - n. 5
- Date d'édition : 05/2017
- DOI : http://dx.doi.org/10.5545/sv-jme.2016.4247
Liens
Voir la source
Indexation
-
Performance of non-flammable azeotropic HFO-123...
- Auteurs : LEE Y., KANG D. G., JUNG D.
- Date : 2012
- Langues : Anglais
- Source : Inha University, Department of Mechanical Engineering, Incheon
Voir la fiche
-
Performance of virtually non-flammable azeotrop...
- Auteurs : LEE Y., KANG D. G., JUNG D.
- Date : 06/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Formats : PDF
Voir la fiche
-
Experimental analysis of R1234yf as a drop-in r...
- Auteurs : NAVARRO-ESBRÍ J., MENDOZA MIRANDA J. M., MOTA BABILONI A., et al.
- Date : 05/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
Voir la fiche
-
Second law analysis of an automotive air condit...
- Auteurs : GOLZARI S., KASAEIAN A., DAVIRAN S., et al.
- Date : 01/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 73
- Formats : PDF
Voir la fiche
-
Experimental analysis of the internal heat exch...
- Auteurs : NAVARRO-ESBRÍ J., MOLÉS F., BARRAGÁN-CERVERA A.
- Date : 09/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 59 - n. 1-2
Voir la fiche