Document IIF
Performance du mélange azéotropique virtuellement non inflammable HFO1234yf/HFC134a pour les applications du HFC134a.
Performance of virtually non-flammable azeotropic HFO1234yf/HFC134a mixture for HFC134a applications.
Auteurs : LEE Y., KANG D. G., JUNG D.
Type d'article : Article, Article de la RIF
Résumé
In this study, ‘drop-in’ performance of R134a, R1234yf and R1234yf/R134a mixture at three compositions of 5, 10, and 15% R134a is measured in a heat pump bench tester under summer and winter conditions. Test results show that the COP, capacity, discharge temperature of R1234yf and R1234yf/R134a mixture are similar to those of R134a. For R1234yf/R134a mixture, flammability decreases as more R134a is added and at compositions of more than 10% of R134a, the mixture becomes non-flammable. The amount of charge for R1234yf and R1234yf/R134a mixture is up to 11% lower than that of R134a. Since R1234yf/R134a mixture with 10-11% R134a is virtually non-flammable and azeotropic and has no ODP and GWP of less than 150 meeting the requirement of European mobile air-conditioner directive, it can be used as an environmentally friendly solution for various R134a applications including mobile air-conditioners with minor modifications.
Documents disponibles
Format PDF
Pages : 1203-1207
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Performance of virtually non-flammable azeotropic HFO1234yf/HFC134a mixture for HFC134a applications.
- Identifiant de la fiche : 30008072
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 4
- Date d'édition : 06/2013
Liens
Voir d'autres articles du même numéro (21)
Voir la source
Indexation
-
Thèmes :
HFC;
Conditionnement d'air mobile;
Mélanges - Mots-clés : R134a; R1234yf; Remplacement immediat; Performance; Mélange azéotropique; Inflammabilité; Frigorigène; Conditionnement d'air
-
Performance of non-flammable azeotropic HFO-123...
- Auteurs : LEE Y., KANG D. G., JUNG D.
- Date : 2012
- Langues : Anglais
- Source : Inha University, Department of Mechanical Engineering, Incheon
Voir la fiche
-
Second law analysis of an automotive air condit...
- Auteurs : GOLZARI S., KASAEIAN A., DAVIRAN S., et al.
- Date : 01/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 73
- Formats : PDF
Voir la fiche
-
Drop-in performance analysis and effect of IHX ...
- Auteurs : DIREK M., KELESOGLU A., AKIN A.
- Date : 05/2017
- Langues : Anglais
- Source : Strojniski vestnik - Journal of mechanical Engineering - vol. 63 - n. 5
- Formats : PDF
Voir la fiche
-
Application of low global warming potential ref...
- Auteurs : FUJITAKA A., SHIMIZU T., SATO S., et al.
- Date : 17/02/2010
- Langues : Anglais
- Source : Measures to address climate change. 2010 International Symposium on Next-generation Air Conditioning and Refrigeration Technology: February 17-19, Tokyo, Japan.
- Formats : PDF
Voir la fiche
-
Flammability investigation of different refrige...
- Auteurs : GRAZ M., WUITZ U.
- Date : 02/2008
- Langues : Anglais
- Source : Obrist Eng. - 28 p.; fig.; phot.; tabl.; append.
Voir la fiche