Document IIF

Analyse des caractéristiques expérimentales du réfrigérateur Joule-Thomson à cycle fermé fonctionnant avec un mélange de frigorigènes azote-hydrocarbure en modes transitoires. 

Experimental characteristics analysis of the closed‐cycle Joule–Thomson refrigerator operating with a nitrogen‐hydrocarbon refrigerant mixture in transient modes.

Numéro : 0055

Auteurs : BYCHKOV E.

Résumé

The search for patterns and analysis of processes occurring in non‐stationary (transient) modes of operation is crucial for improving and increasing the energy efficiency of closed‐cycle Joule‐Thomson (JT) refrigerators that use refrigerant mixtures to cool objects within the temperature range of ‐90…‐160⁰C. The use of multicomponent mixtures (more than 3 components) in these refrigerators to achieve low temperatures results not only in a change in the mixture's vapor‐liquid equilibrium during temperature decrease in transient operating modes but also in a shift in molar concentrations between the components in the circulating composition. This paper presents an analysis of the experimental determination of molar concentrations of a nitrogen‐hydrocarbon refrigerant mixture in transient operating modes, conducted in the temperature range up to ‐163⁰C on a JT refrigerator with a 4.36 m3/h volumetric capacity compressor. The results obtained can serve as initial data for further development of a method to determine the optimal pressure change law in the evaporator, and the acquired experimental relationships can be utilized for designing low‐performance JT refrigerators (with a compressor volumetric flow rate of less than 25 m3/h) operating with mixtures to achieve the maximum cooling capacity at intermediate temperature levels.

Documents disponibles

Format PDF

Pages : 12 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Experimental characteristics analysis of the closed‐cycle Joule–Thomson refrigerator operating with a nitrogen‐hydrocarbon refrigerant mixture in transient modes.
  • Identifiant de la fiche : 30031694
  • Langues : Anglais
  • Sujet : Technologie
  • Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
  • Date d'édition : 21/08/2023
  • DOI : http://dx.doi.org/10.18462/iir.icr.2023.0055

Liens


Voir d'autres communications du même compte rendu (491)
Voir le compte rendu de la conférence