Analyse des performances du système de refroidissement d’un centre de données : étude de cas.
Data center cooling system performance analysis: a case study.
Auteurs : ADHIKARY P., PRAKASH D., DE S., et al.
Résumé
As global demand for data exchange grows, so too does the size and load place on data centers, placing unprecedented constraints on space and power available to the operator. Data centers are dedicated facilities which support business critical IT servers. Tightly packed server racks are generating exponentially more computer power and most of this is converted into rejected heat. Hence a flexible, high efficiency range of cooling solutions which optimizes the performance of the equipment, as well as managing the environmental impact of the data centre are highly needed by IT industry. The data center industry is growing rapidly and is focusing more and more on efficiency and maximum uptime. With more capacity and higher density there is a need for energy efficient cooling of the IT equipments as shown in this study. Good agreement was found between the simulated results and obtained project data.
Documents disponibles
Format PDF
Pages : 4
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Data center cooling system performance analysis: a case study.
- Identifiant de la fiche : 30024792
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Date d'édition : 27/07/2018
Liens
Voir d'autres communications du même compte rendu (29)
Voir le compte rendu de la conférence
-
Best practices of energy-efficient design for a...
- Auteurs : WANG F. J., LAI C. M., HUANG Y. S., et al.
- Date : 16/06/2013
- Langues : Anglais
- Source : Clima 2013. 11th REHVA World Congress and 8th International Conference on Indoor Air Quality, Ventilation and Energy Conservation in Buildings.
- Formats : PDF
Voir la fiche
-
The effect of vents arrangement on the energy e...
- Auteurs : WU Y. L., KUAN Y. D., WANG J. Y., et al.
- Date : 07/06/2010
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Formats : PDF
Voir la fiche
-
Into the cold.
- Auteurs : FLUCKER S., TOZER R.
- Date : 04/2012
- Langues : Anglais
- Source : CIBSE Journal - vol. 4 - n. 4
Voir la fiche
-
Optimizing data center energy consumption.
- Auteurs : PURKAYASTHA I.
- Date : 27/07/2018
- Langues : Anglais
- Source : Proceedings of the International Conference on Emerging Technologies for Sustainable and Intelligent HVAC&R Systems, Kolkata, July 27-28 2018.
- Formats : PDF
Voir la fiche
-
With computational fluid dynamics, data center ...
- Date : 02/2008
- Langues : Anglais
- Source : HPAC Engineering - vol. 81 - n. 2
Voir la fiche