Displacement ventilation (DV) has been widely studied in literature, and is currently used in enclosed environments like office buildings. Although DV has been shown to be able to provide better indoor air quality in the occupied zone than conventional mixing ventilation (MV), its capability of removing heat is usually limited. Since it supplies air directly to occupied zone, the temperature of supply air is inevitably higher than that in MV. Meanwhile, passive chilled beams (PCB), which cool occupied space by running chilled water through beams at ceiling level, has been reported to have a high heat removal capability, and can save energy. Thus, a coupled system that combines both DV and PCB has the potential of keeping the advantages of both systems, and was explored in detailed by using experimental and simulation methods. This study focused on investigating the thermal performance of a coupled system of DV and PCB, and compared it with a corresponding DV-only system. Experiment was carried out in a full-scale environmental chamber to measure air velocity and temperature at various locations in the chamber. Moreover, a computational fluid dynamics (CFD) model was used to simulate the air velocity and temperature distributions, which were then validated by the measured data. With the validated CFD model, thermal comfort in the occupied zone were analyzed with the coupled system and the DV-only system. Thermal comfort level was presented by the predicted mean vote (PMV), and percentage dissatisfied people due to draft (PD). The results indicated that the PCB can help to cool down the temperature in the room, and the air temperature stratification was still observed in most regions. Meanwhile, due to the cold downward jet generated by the PCB, the region under the PCB had a higher air velocity and lower temperature than that with DV-only system. This resulted in a local zone with less thermal comfort. Based on reported results, this study provided preliminary guidelines for designing of the coupled system with acceptable thermal comfort in occupied zone.
Documents disponibles
Format PDF
Pages : 10
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Thermal comfort analysis in a room with displacement ventilation system coupled with passive chilled beams.
- Identifiant de la fiche : 30024730
- Langues : Anglais
- Source : 2018 Purdue Conferences. 5th International High Performance Buildings Conference at Purdue.
- Date d'édition : 09/07/2018
Liens
Voir d'autres communications du même compte rendu (88)
Voir le compte rendu de la conférence
Indexation
- Thèmes : Conditionnement d'air pour le confort
- Mots-clés : Environnement intérieur; CFD; Ventilation; Performance; Modélisation; Poutre froide; Confort thermique; Eau glacée
-
Geometric optimization on active chilled beam t...
- Auteurs : GUAN Z., WEN C.
- Date : 05/04/2016
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 98
Voir la fiche
-
Flow pattern and thermal comfort in office envi...
- Auteurs : KOSKELA H., HÄGGBLOM H., KOSONEN R., et al.
- Date : 08/2012
- Langues : Anglais
- Source : HVAC&R Research - vol. 18 - n. 4
Voir la fiche
-
The air distribution around nozzles based on ac...
- Auteurs : WU B., CAI W., WANG Q., et al.
- Date : 11/07/2016
- Langues : Anglais
- Source : 2016 Purdue Conferences. 4th International High Performance Buildings Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Finding the proper position of supply and retur...
- Auteurs : RAHVARD A. J., KARAMI S., LAKZIAN E.
- Date : 01/2023
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Formats : PDF
Voir la fiche
-
Coupling CFD and human body thermoregulation mo...
- Auteurs : GAO N., NIU J., ZHANG H.
- Date : 07/2006
- Langues : Anglais
- Source : HVAC&R Research - vol. 12 - n. 3
Voir la fiche