Document IIF
Analyse exergétique d’un système frigorifique au CO2 transcritique avec et sans échangeur de chaleur interne, en utilisant des données expérimentales.
Exergic analysis of CO2 trans-critical refrigeration system with and without internal heat exchanger using experimental data.
Numéro : pap. 76
Auteurs : PUROHIT N., GUPTA D. K., DASGUPTA M. S.
Résumé
This paper presents exergetic analysis of a CO2 trans-critical refrigeration system based on experimental data for warm weather condition up to 45oC.Results from configuration with and without internal heat exchanger (IHX) are compared for their performance at two different evaporator temperatures(0oC and -5oC) and gas cooler air flow velocity within range 1 m·s-1 to 3 m·s-1. The experimental results demonstrate the relative advantage of use of IHX for high ambient operation. For cycle with IHX, the maximum enhancement in exergy efficiency is found to be 5.05 % at 0oC evaporator temperature while the same is found 4.60 % at -5oC evaporator temperature. Component wise, compressor followed by gas cooler are found to have highest exergy destruction while that in IHXis found to bethe least.
Documents disponibles
Format PDF
Pages : 9
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Exergic analysis of CO2 trans-critical refrigeration system with and without internal heat exchanger using experimental data.
- Identifiant de la fiche : 30023432
- Langues : Anglais
- Source : 5th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Beijing, Chine, 6-8 avril 2018
- Date d'édition : 06/04/2018
- DOI : http://dx.doi.org/10.18462/iir.iccc.2018.0076
Liens
Voir d'autres communications du même compte rendu (72)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
CO2;
Efficacité energétique, économie d'énergie - Mots-clés : Système frigorifique; Exergie; R744; Experimentation; Échangeur de chaleur; CO2; Climat chaud
-
R744 refrigeration technologies for supermarket...
- Auteurs : HAFNER A., HEMMINGSEN A. K.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
System configurations for supermarkets in warm ...
- Auteurs : HAFNER A., HEMMINGSEN A. K., NEKSÅ P.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Energy and environmental comparison of commerci...
- Auteurs : GULLO P., CORTELLA G., POLZOT A.
- Date : 07/04/2016
- Langues : Anglais
- Source : 4th IIR International Conference on Sustainability and the Cold Chain. Proceedings: Auckland, New Zealand, April 7-9, 2016.
- Formats : PDF
Voir la fiche
-
Energy and environmental performance assessment...
- Auteurs : GULLO P., ELMEGAARD B., CORTELLA G.
- Date : 04/2016
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 64
- Formats : PDF
Voir la fiche
-
Recent installations of CO2 supermarket refrige...
- Auteurs : MINETTO S., GIROTTO S., SALVATORE M., et al.
- Date : 23/06/2014
- Langues : Anglais
- Source : 3rd IIR International Conference on Sustainability and the Cold Chain. Proceedings: London, UK, June 23-25, 2014
- Formats : PDF
Voir la fiche