Document IIF
Analyse expérimentale d'une pompe à chaleur au R744 équipée d'un éjecteur.
Experimental analysis of a R744 heat pump equipped with an ejector.
Numéro : pap. n. 279
Auteurs : MINETTO S., BRIGNOLI R., BANASIAK K., et al.
Résumé
This paper presents the experimental analysis of a prototype R744 water/water heat pump (5 kW heating power at 0°C evaporation temperature, 100 bar gas cooler pressure, 35°C gas cooler outlet temperature) which was equipped with a two-phase ejector. According to the traditional lay-out, the energy that was recovered from the expansion process inside the ejector improved the circulation of refrigerant through the evaporator. The same heat pump was also provided with a back-pressure valve as the expansion device, i.e. a direct comparison of the performance was possible between the heat pump systems, either equipped with the ejector or the expansion valve. Tests were performed to evaluate the performance when the heat pump produced hot tap water, i.e. heating water from the main waterworks temperature to storage temperature (~60°C). Additionally, an investigation took place to understand how the system performed when space heating was required, i.e. providing hot water with a limited temperature lift, however at relatively high inlet temperatures. Experiments demonstrated that the ejector is helpful to improve the heat pump performance, thus promoting the diffusion of R744 units also for domestic space heating and air conditioning. Technological problems related to lubricant recovery were found.
Documents disponibles
Format PDF
Pages : 8 p.
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Experimental analysis of a R744 heat pump equipped with an ejector.
- Identifiant de la fiche : 30004642
- Langues : Anglais
- Source : 10th IIR-Gustav Lorentzen Conference on Natural Working Fluids (GL2012). Proceedings. Delft, The Netherlands, June 25-27, 2012.
- Date d'édition : 25/06/2012
Liens
Voir d'autres communications du même compte rendu (142)
Voir le compte rendu de la conférence
Indexation
-
Performance assessment of an off-the-shelf R744...
- Auteurs : MINETTO S., BRIGNOLI R., BANASIAK K., et al.
- Date : 09/2013
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 59 - n. 1-2
Voir la fiche
-
Experimental investigation on transcritical CO2...
- Auteurs : WEI J., CHEN Q., TANG L., et al.
- Date : 16/08/2015
- Langues : Anglais
- Source : Proceedings of the 24th IIR International Congress of Refrigeration: Yokohama, Japan, August 16-22, 2015.
- Formats : PDF
Voir la fiche
-
Simulation and exergy analysis of transcritical...
- Auteurs : METSUE A., NESREDDINE H., MONNEY D., BARTOSIEWICZ Y., PONCET S.
- Date : 21/08/2023
- Langues : Anglais
- Source : Proceedings of the 26th IIR International Congress of Refrigeration: Paris , France, August 21-25, 2023.
- Formats : PDF
Voir la fiche
-
Experimental investigation on the performance o...
- Auteurs : BOCCARDI G., BOTTICELLA F., LILLO G., et al.
- Date : 10/2017
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 82
- Formats : PDF
Voir la fiche
-
Characteristics of a two-phase ejector in carbo...
- Auteurs : AKAGI S., WANG J. F., HIHARA E.
- Date : 02/05/2005
- Langues : Anglais
- Source : 8th IEA Heat Pump Conference 2005: global advances in heat pump technology, applications, and markets. Conference proceedings [CD-ROM].
Voir la fiche