Résumé
General exergy models on conventional district cooling system (DCS), natural water-cooled DCS and air-cooled DCS were presented based on the first and the second law of thermodynamics. A commercial building district in Shanghai was discussed as a case study. Dynamic energy and exergy analysis models of three kinds of DCS using the TRNSYS software were developed. And, exergy loss,exergetic efficiency and COP on an hourly basis of three kinds of DCS were analyzed. Furthermore, a method to determine the longest pipeline length from natural water source to chillers of natural water-cooled DCS was presented when natural water-cooled DCS is better than the other two kinds of DCS based on COP and exergetic efficiency. The results of the case study show that the exergetic efficiency of natural water-cooled DCS is the highest, air-cooled DCS the second, and conventional DCS the lowest. The exergetic efficiency for the three kinds of DCS is 16.52%,15.05% and 12.12% respectively, and the exergy loss per unit of cold energy is 0.289, 0.323 and 0.414 respectively. In addition, the COP of natural water-cooled DCS is the highest, conventional DCS the second, and air-cooled DCS the lowest, with the values of 2.52, 2.32 and 2.2 respectively.
Documents disponibles
Format PDF
Pages : 69-77
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : [In Chinese. / En chinois.]
- Identifiant de la fiche : 30010101
- Langues : Chinois
- Source : Journal of Refrigeration - vol. 34 - n. 151
- Date d'édition : 06/2013
- DOI : http://dx.doi.org/10.3969/j.issn.0253-4339.2013.03.069
Liens
Voir d'autres articles du même numéro (9)
Voir la source
Indexation
- Thèmes : Froid et chauffage urbain
- Mots-clés : Exergie; Énergie; Chine; Froid urbain; Modèle; Étude de cas
-
Chauffage en Suède : chauffage et froid urbains.
- Auteurs : TANAKA I.
- Date : 2011
- Langues : Japonais
- Source : SHASE - vol. 85 - n. 11
Voir la fiche
-
Analyse d'une installation de froid urbain.
- Auteurs : MA J., CHEN J., LI C., et al.
- Date : 03/2012
- Langues : Chinois
- Source : HV & AC - vol. 42 - n. 261
- Formats : PDF
Voir la fiche
-
Les réseaux de froid et leur impact environneme...
- Auteurs : LAIGROZ P., SENEJEAN B., BEN ALLEL A., et al.
- Date : 09/2010
- Langues : Français
- Source : Revue générale du Froid & du Conditionnement d'air - vol. 100 - n. 1106
Voir la fiche
-
Le système de chauffage et de refroidissement u...
- Auteurs : YANAGIHARA R., MIYAMOTO K., HAGIWARA T., et al.
- Date : 2004
- Langues : Japonais
- Source : SHASE - vol. 78 - n. 10
Voir la fiche
-
India's first district cooling system at GIFT c...
- Auteurs : PATEL G.
- Date : 12/2017
- Langues : Anglais
- Source : Air Conditioning and Refrigeration Journal - vol. 20 - n. 5
- Formats : PDF
Voir la fiche