Summary
General exergy models on conventional district cooling system (DCS), natural water-cooled DCS and air-cooled DCS were presented based on the first and the second law of thermodynamics. A commercial building district in Shanghai was discussed as a case study. Dynamic energy and exergy analysis models of three kinds of DCS using the TRNSYS software were developed. And, exergy loss,exergetic efficiency and COP on an hourly basis of three kinds of DCS were analyzed. Furthermore, a method to determine the longest pipeline length from natural water source to chillers of natural water-cooled DCS was presented when natural water-cooled DCS is better than the other two kinds of DCS based on COP and exergetic efficiency. The results of the case study show that the exergetic efficiency of natural water-cooled DCS is the highest, air-cooled DCS the second, and conventional DCS the lowest. The exergetic efficiency for the three kinds of DCS is 16.52%,15.05% and 12.12% respectively, and the exergy loss per unit of cold energy is 0.289, 0.323 and 0.414 respectively. In addition, the COP of natural water-cooled DCS is the highest, conventional DCS the second, and air-cooled DCS the lowest, with the values of 2.52, 2.32 and 2.2 respectively.
Available documents
Format PDF
Pages: 69-77
Available
Public price
20 €
Member price*
15 €
* Best rate depending on membership category (see the detailed benefits of individual and corporate memberships).
Details
- Original title: [In Chinese. / En chinois.]
- Record ID : 30010101
- Languages: Chinese
- Source: Journal of Refrigeration - vol. 34 - n. 151
- Publication date: 2013/06
- DOI: http://dx.doi.org/10.3969/j.issn.0253-4339.2013.03.069
Links
See other articles in this issue (9)
See the source
Indexing
- Themes: District cooling and heating
- Keywords: Exergy; Energy; China; District cooling; Model; Case study
-
Heating in Sweden: district heating and cooling.
- Author(s) : TANAKA I.
- Date : 2011
- Languages : Japanese
- Source: SHASE - vol. 85 - n. 11
View record
-
Analysis of a district cooling system.
- Author(s) : MA J., CHEN J., LI C., et al.
- Date : 2012/03
- Languages : Chinese
- Source: HV & AC - vol. 42 - n. 261
- Formats : PDF
View record
-
Les réseaux de froid et leur impact environneme...
- Author(s) : LAIGROZ P., SENEJEAN B., BEN ALLEL A., et al.
- Date : 2010/09
- Languages : French
- Source: Revue générale du Froid & du Conditionnement d'air - vol. 100 - n. 1106
View record
-
India's first district cooling system at GIFT c...
- Author(s) : PATEL G.
- Date : 2017/12
- Languages : English
- Source: Air Conditioning and Refrigeration Journal - vol. 20 - n. 5
- Formats : PDF
View record
-
The Harumi Island DHC system.
- Author(s) : YANAGIHARA R., MIYAMOTO K., HAGIWARA T., et al.
- Date : 2004
- Languages : Japanese
- Source: SHASE - vol. 78 - n. 10
View record