Résumé

This paper demonstrates that the performance of a mobile air conditioning system (with a microchannel evaporator modified to be single pass) operating normally with R134a in direct expansion mode can be significantly improved when switched to flash gas bypass (FGB) mode. When operated at the same compressor speed, the system in FGB mode produces about 13–18% more cooling capacity at 4–7% higher COP than DX mode. When the compressor speed was adjusted to maintain the same cooling capacity, the COP improved 37–55%. Two main reasons are identified and discussed: 1) improved refrigerant distribution and 2) reduction of refrigerant pressure drop.

Documents disponibles

Format PDF

Pages : 1869-1877

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Flash gas bypass in mobile air conditioning system with R134a.
  • Identifiant de la fiche : 30005898
  • Langues : Anglais
  • Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 7
  • Date d'édition : 11/2012

Liens