Résumé
This paper demonstrates that the performance of a mobile air conditioning system (with a microchannel evaporator modified to be single pass) operating normally with R134a in direct expansion mode can be significantly improved when switched to flash gas bypass (FGB) mode. When operated at the same compressor speed, the system in FGB mode produces about 13–18% more cooling capacity at 4–7% higher COP than DX mode. When the compressor speed was adjusted to maintain the same cooling capacity, the COP improved 37–55%. Two main reasons are identified and discussed: 1) improved refrigerant distribution and 2) reduction of refrigerant pressure drop.
Documents disponibles
Format PDF
Pages : 1869-1877
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Flash gas bypass in mobile air conditioning system with R134a.
- Identifiant de la fiche : 30005898
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 35 - n. 7
- Date d'édition : 11/2012
Liens
Voir d'autres articles du même numéro (24)
Voir la source
Indexation
-
Thèmes :
HFC;
Conditionnement d'air mobile - Mots-clés : Écoulement diphasique; R134a; Automobile; Microcanal; Puissance; Performance; Évaporateur; Frigorigène; Conditionnement d'air; Distribution
-
Numerical simulation of three dimensional two-p...
- Auteurs : STEVANOVIC V. D., HRNJAK P.
- Date : 05/05/2017
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 117
Voir la fiche
-
Investigating performance of microchannel evapo...
- Auteurs : SHI J., QU X., QI Z., et al.
- Date : 01/2011
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 34 - n. 1
- Formats : PDF
Voir la fiche
-
Untersuchung des Öleinflusses auf das Leistungs...
- Auteurs : BURGER R., KLUG P.
- Date : 05/2002
- Langues : Allemand
- Source : KI Luft Kältetech. - vol. 38 - n. 5
Voir la fiche
-
Cycle performances of the mixture HFC-161 + HFC...
- Auteurs : HAN X. H., LI P., XU Y. J., et al.
- Date : 05/2013
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 36 - n. 3
- Formats : PDF
Voir la fiche
-
Performance enhancement study of mobile air con...
- Auteurs : QI Z., ZHAO Y., CHEN J.
- Date : 03/2010
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 33 - n. 2
- Formats : PDF
Voir la fiche