Comparaison de la configuration des écoulements linéaire et turbulent dans des salles blanches employant ces types d'écoulement.
Comparison of flow patterns between line-type clean room and turbulent type clean room.
Auteurs : LEE Y. C., CHOU Y. W., YANG B. C., et al.
Résumé
This study aimed at the flow pattern comparisons between line-type clean room and turbulent-type clean room with limitation of clean space. Using multiple components and transient model simulated the flow patterns and air-exchange efficiency of two type clean rooms with cleanliness 1000. The simulation results present that the air-exchange efficiency of in line-type clean room is 0.62 which is comparable to idealized unidirectional-type clean room the air-exchange efficiency is 1. And, the air-exchange efficiency is better than that of turbulent type-clean room 0.37 with the same circulation flow rate.
Documents disponibles
Format PDF
Pages : pp. 612-617
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Comparison of flow patterns between line-type clean room and turbulent type clean room.
- Identifiant de la fiche : 2010-0915
- Langues : Anglais
- Source : ACRA-2009. The proceedings of the 4th Asian conference on refrigeration and air conditioning: May 20-22, 2009, Taipei, R.O.C.
- Date d'édition : 20/05/2009
Liens
Voir d'autres communications du même compte rendu (102)
Voir le compte rendu de la conférence
Indexation
-
Mikroorganismen in laminarer und turbulenter St...
- Auteurs : DKV, SCHEER A., FITZNER K.
- Date : 19/11/1997
- Langues : Allemand
- Source : DKV-Tagungsbericht 24. 1997, Hamburg.
Voir la fiche
-
Analysis of the contaminant distribution in a t...
- Auteurs : YANG J., LI X., YAN Q., et al.
- Date : 09/07/2000
- Langues : Anglais
- Source : Air distribution in rooms: ventilation for health and sustainable environment. Roomvent 2000. Proceedings of the 7th international conference.
Voir la fiche
-
NUMERICAL ANALYSIS OF CONTAMINANTS DIFFUSION IN...
- Auteurs : OH M. D.
- Date : 01/08/1989
- Langues : Anglais
Voir la fiche
-
Clean operating room control.
- Auteurs : XU Z. L., SHEN J. M.
- Date : 2005
- Langues : Anglais
- Source : ASHRAE Transactions. 2005 Annual Meeting, Denver, Colorado, USA. Volume 111, part 2 + CD-ROM.
Voir la fiche
-
Application of CFD airflow design for clean rooms.
- Auteurs : QI W., HUANG W. H.
- Date : 21/05/2006
- Langues : Anglais
- Source : ACRA-2006. Proceedings of the 3rd Asian conference on refrigeration and air conditioning.
Voir la fiche