Comparaison des performances des transformateurs de chaleur à absorption avec les différentes approches d’assistance par compression utilisées pour le chauffage à basse température.

Performance comparison of absorption heat transformers with different compression-assisted approaches used for low-temperature heating.

Numéro : AB-YR2-1015

Auteurs : WANG J., WANG B., LI X., et al.

Résumé

The energy consumption of building heating increases continuously. The efficiency of a low-temperature heating system, compression-assisted absorption heat transformer (CAHT), can become higher when ambient air temperature decreases. There are two compression-assisted approaches, and the two different CAHTs using them are compared with each other in present study. Consequently, the COP of CAHT increases with the decrease of ambient temperature, and the performance of high-pressure boosting CAHT is better.

Détails

  • Titre original : Performance comparison of absorption heat transformers with different compression-assisted approaches used for low-temperature heating.
  • Identifiant de la fiche : 30022772
  • Langues : Anglais
  • Source : International sorption heat pump conference, ISHPC 2017, Tokyo august 7-10.
  • Date d'édition : 07/08/2017

Liens


Voir d'autres communications du même compte rendu (159)
Voir le compte rendu de la conférence