Document IIF
Concept frigorifique pour les petits supermarchés employant des systèmes modulaires en cascade au dioxyde de carbone et au propylène.
Refrigerating concept for small supermarkets using multiple modular cascade systems with carbon dioxide and propylene.
Auteurs : HEERUP C.
Résumé
The concept addresses the safety issues involved with hydrocarbons by minimizing the refrigerant charge and containing the hydrocarbon filled parts in a module comprising a closed cabinet. The refrigeration capacity can be satisfied by installing from 3 to 10 modules in parallel. If one module fails, the remaining will in most cases suffice as back up capacity until replacement. The modules contain each a refrigerant charge of maximum one kilogram propylene serving as the upper stage of a cascade system. The condensers for the upper stages are cooled by a conventional dry cooler circuit. The upper stage is cooling the primary side of a plate heat exchanger, the secondary side acting as condenser for carbon dioxide as the secondary refrigerant. The liquid carbon dioxide is pumped to the low temperature display cabinets via expansion valves and is returned to the condenser by multiple rolling piston compressors, thus completing the low stage of the cascade system. The medium temperature display cabinets are simply pump fed via solenoid valves with liquid carbon dioxide which partly or totally evaporates and then returns to the condenser.
Documents disponibles
Format PDF
Pages : 2004-2
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerating concept for small supermarkets using multiple modular cascade systems with carbon dioxide and propylene.
- Identifiant de la fiche : 2005-1900
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Date d'édition : 01/08/2004
Liens
Voir d'autres communications du même compte rendu (105)
Voir le compte rendu de la conférence
Indexation
-
Opportunities for CO2 in supermarket refrigerat...
- Auteurs : VERHOEF P. J.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche
-
Supermarket refrigeration system charge reducti...
- Auteurs : SHARMA V., FRICKE B., BANSAL P.
- Date : 02/08/2014
- Langues : Anglais
- Source : 11th IIR Gustav Lorentzen Conference on Natural Refrigerants (GL2014). Proceedings. Hangzhou, China, August 31-September 2, 2014.
- Formats : PDF
Voir la fiche
-
Laboratory tests of NH3/CO2 cascade system for ...
- Auteurs : SAWALHA S., ROGSTAM J., NILSSON P. O.
- Date : 30/08/2005
- Langues : Anglais
- Source : Commercial Refrigeration. Thermophysical Properties and Transfer Processes of Refrigerants. Proceedings of the IIR International Conferences.
- Formats : PDF
Voir la fiche
-
Natural refrigerants in supermarket refrigeration.
- Auteurs : ELEFSEN F.
- Date : 02/05/2001
- Langues : Anglais
- Source : AIRAH 2001 National Conference Proceedings.
Voir la fiche
-
Analysis of advanced, low-charge refrigeration ...
- Auteurs : WALKER D. H., BAXTER V. D.
- Date : 2003
- Langues : Anglais
- Source : ASHRAE Transactions. 2003 Winter Meeting, Chicago, Illinois. Volume 109, part 1 + CD-ROM.