Conception améliorée de meubles de vente frigorifiques utilisés pour les surgelés dans les supermarchés afin de réduire la consommation d'énergie et d'augmenter la puissance frigorifique.

Enhancement of supermarket freezers to reduce energy consumption and increase refrigeration capacity.

Résumé

An auxiliary mixed refrigerant cycle for subcooling of a liquid refrigerant in the main cycle can provide up to 40% increase in the COP of a conventional vapour compression cycle. In addition, an increase in the cooling capacity of up to 100% can translate into a reduction in the size of the whole system by up to 30%. The relatively small size of the auxiliary unit makes it possible to use a packaged design compatible with mixed refrigerants.

Détails

  • Titre original : Enhancement of supermarket freezers to reduce energy consumption and increase refrigeration capacity.
  • Identifiant de la fiche : 1999-3582
  • Langues : Anglais
  • Source : Proceedings of the 1998 Purdue International Refrigeration Conference.
  • Date d'édition : 14/07/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.