Conception, mise en oeuvre et validation réussies de technologies au R744 transcritique pour des distributeurs de boisson réfrigérés.

Successful design, implementation, and validation of transcritical R744 technology for beverage display coolers.

Numéro : pap. 2192

Auteurs : ELBEL S., PADILLA-FUENTES Y., BOWERS C., et al.

Résumé

Glass door merchandisers are used in grocery and convenience stores to display chilled beverages or refrigerated foods. Among other possible choices for this application, carbon dioxide (R744, CO2) is seen as a promising low global warming potential (GWP) refrigerant alternative that is non-flammable and non-toxic. While R744 itself is less costly than some synthetic alternatives, successful implementation of high-performance, low-cost transcritical R744 technology is challenging. This paper summarizes important R744-specific design issues and differences in comparison to conventional R134a bottle coolers. Due to cost reasons, it is highly desired to use relatively conventional components, including round-tube-plate-fin heat exchanger designs, fixed geometry capillary tubes (instead of variable geometry expansion valves), and single-speed compressors. While conventional round-tube-plate-fin evaporator designs deliver acceptable results, transcritical R744 systems require substantially different heat exchanger designs in order to deliver suitable performance when used as gas cooler. Internal heat exchange, which in conventional R134a systems is often achieved by wrapping the capillary tube around the compressor suction line, plays a much more important role in transcritical R744 systems, and shows large performance improvement potential. Experiments also show that proper capillary tube sizing and refrigerant charge optimization have much bigger impact on transcritical R744 systems in terms of cooling performance and energy efficiency in comparison to R134a systems. Presented is an example of a successful R744 bottle cooler design that is on par with a comparable R134a system in terms of performance and cost. This low-cost, high performance design has been implemented and experimentally validated. The improved transcritical R744 system achieved pull down times and energy efficiencies that were comparable with the R134a baseline system results: 97% and 103%, respectively.

Documents disponibles

Format PDF

Pages : 10 p.

Disponible

  • Prix public

    20 €

  • Prix membre*

    15 €

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Successful design, implementation, and validation of transcritical R744 technology for beverage display coolers.
  • Identifiant de la fiche : 30013416
  • Langues : Anglais
  • Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
  • Date d'édition : 14/07/2014

Liens


Voir d'autres communications du même compte rendu (203)