Conductivité thermique intrinsèque et effet de la résistance de contact par les parois dans des générateurs à charbon actif granulaire.
Intrinsic thermal conductivity and wall contact resistance effect in granular active carbon generators.
Numéro : pap. n. 105
Auteurs : RIVERO PACHO A. M., CRITOPH R. E., METCALF S. J.
Résumé
It is acknowledged that the commercial success of adsorption heat pumps or refrigeration systems depend crucially on a good heat and mass transfer in the adsorbent bed. Good heat and mass transfer allow greater specific heating or cooling power which reduces capital costs, producing compact sorption generators, and as well reduces the cycle time of the system. In this study the intrinsic thermal conductivity and thermal contact resistance of vibrated grains and powder samples and binary mixtures of active carbon are investigated and compared using two different thermal conductivity measurement techniques: a flat plate steady state measurement and a hot tube transient measurement. This study draws conclusions on the way that particle size and distribution, binary mixture ratio and bulk density affect the overall thermal performance of the adsorbent. Different carbon grain sizes were tested, ranging from 1.68 mm to fine powder, 1 µm. For each grain size three binary mixtures (2/3 grains – 1/3 powder, 1/2 grains – 1/2 powder and 1/3 grains – 2/3 powder) and grains and powder on their own were tested. The binary mixtures show higher densities (up to 750 kg/m3) and as a consequence higher thermal conductivities (0.32 W/(mK)) and lower wall contact resistances (equivalent air contact layer thickness of 0.005 mm) than only grains or powder samples.
Documents disponibles
Format PDF
Pages : 10 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Intrinsic thermal conductivity and wall contact resistance effect in granular active carbon generators.
- Identifiant de la fiche : 30013750
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Date d'édition : 02/03/2014
Liens
Voir d'autres communications du même compte rendu (125)
Voir le compte rendu de la conférence
-
Optimization potentials for the absorber and th...
- Auteurs : MIRL N., SPINDLER K.
- Date : 24/08/2019
- Langues : Anglais
- Source : Proceedings of the 25th IIR International Congress of Refrigeration: Montréal , Canada, August 24-30, 2019.
- Formats : PDF
Voir la fiche
-
Dynamic analysis of a single adsorbent particle...
- Auteurs : YILDIRIM Z. E., MOBEDI M., ULKU S.
- Date : 02/03/2014
- Langues : Anglais
- Source : International sorption heat pump conference (ISHPC2014), College Park, United States, March 31-April 2, 2014.
- Formats : PDF
Voir la fiche
-
Numerical model of ammonia-water absorption ins...
- Auteurs : GOMMED K., GROSSMAN G., KOENIG M.
- Date : 24/03/1999
- Langues : Anglais
- Source : Proceedings of the International Sorption Heat Pump Conference.
Voir la fiche
-
Study state simulation of absorption type heat ...
- Auteurs : WADA D., OHNO K., SAITO K.
- Date : 06/04/2011
- Langues : Anglais
- Source : Sources/sinks Alternative to the Outside Air for Heat Pump and Air-conditioning Techniques (Alternative Sources - AS), Padua, Italy, April 5-7, 2011. / International Sorption Heat Pump Conference (ISHPC11), Padua, Italy, April 6-8, 2011.
- Formats : PDF
Voir la fiche
-
Match property analysis of falling film absorpt...
- Auteurs : HU T., XIE X., JIANG Y., et al.
- Date : 07/08/2017
- Langues : Anglais
- Source : International sorption heat pump conference, ISHPC 2017, Tokyo august 7-10.
Voir la fiche