Document IIF

Conversion d'un réfrigérateur domestique pour qu'il fonctionne avec des mélanges de HFC-134A/HC-600a et de l'huile minérale.

Retrofitting of a domestic refrigerator with blends of HFC-134a/HC-600a to use mineral oil.

Auteurs : DEVOTTA S., KUMAR V. S., JOSHI R. V., et al.

Résumé

A 165-litre Indian domestic refrigerator was retrofitted to use HFC-134a/HC-600a blends with mineral oil as drop-in substitutes to CFC-12. In order to optimize the performance, three compositions of the blend with three different charges each were studied. A rated energy consumption test, a no-load pull-down test and an ice-making test were conducted. It was observed that there was a loss of cooling capacity due to retrofitting. The HFC-134a/HC-600a (96%/4% by weight) blend gave the best results.

Documents disponibles

Format PDF

Pages : 2001-5

Disponible

  • Prix public

    20 €

  • Prix membre*

    Gratuit

* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)

Détails

  • Titre original : Retrofitting of a domestic refrigerator with blends of HFC-134a/HC-600a to use mineral oil.
  • Identifiant de la fiche : 2003-0790
  • Langues : Anglais
  • Source : Thermophysical Properties and Transfer Processes of New Refrigerants.
  • Date d'édition : 03/10/2001

Liens


Voir d'autres communications du même compte rendu (60)
Voir le compte rendu de la conférence