Développement d'une pompe à chaleur à absorption à ammoniac pour des applications résidentielles chez LG Electronics.

Development of ammonia absorption heat pump for residential use in LG Electronics.

Auteurs : LEE D., KIM D., OH S.

Résumé

Recent studies about the development of GAX (generator, absorber, heat exchanger) ammonia/water absorption heat pump of 3 refrigeration tours cooling capacity is briefly described. The objective of the study is to develop and launch at high performance gas-fired absorption heat pump for residential use into the Korean market. A GAX cycle was adopted for the prototype machine to maximise its cooling performance. The test results showed a cooling cycle COP of 0.64 and heating cycle COP of 1.49. Data from the test were thoroughly analyzed and some conclusions were made. Several modifications will be made in the near future to get higher COP.

Détails

  • Titre original : Development of ammonia absorption heat pump for residential use in LG Electronics.
  • Identifiant de la fiche : 2000-1838
  • Langues : Anglais
  • Source : Absorption machines for heating and cooling in future energy systems. Workshop proceedings.
  • Date d'édition : 28/10/1998
  • Document disponible en consultation à la bibliothèque du siège de l'IIF uniquement.

Liens


Voir d'autres communications du même compte rendu (14)
Voir le compte rendu de la conférence