Diffuseur d'air et efficacité de la ventilation.
Terminali per la diffusione dell'aria ed efficienza di ventilazione.
Auteurs : BASSO R. A.
Résumé
The ventilation rate provided in the Standard UNI 10339 leaves the kind of installation and the air diffusion system out of consideration; in fact the ventilation rate really involved in internal pollutant dilution fluctuates as a function of the air-diffusion system. To consider this effect, in the reviewing of the standard, the concept of ventilation effectiveness has been introduced; it supplies a type of measurement of the ventilation air flow really used for indoor pollutant dilution, compared with the total supply air flow. As use of a qualitative index to express pollutant dilution would be difficult to carry out, a thermal index designed to put the diffuser air induction performance in touch with the air mixing one is proposed. Ventilation effectiveness becomes a parameter for air diffuser selection that considers their performances, in order to achieve the best indoor air quality.
Détails
- Titre original : Terminali per la diffusione dell'aria ed efficienza di ventilazione.
- Identifiant de la fiche : 2006-2007
- Langues : Italien
- Sujet : Réglementation
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
- Date d'édition : 07/03/2002
Liens
Voir d'autres communications du même compte rendu (32)
Voir le compte rendu de la conférence
Indexation
-
Filtrazione e purificazione dell'aria tra evolu...
- Auteurs : GENGHINI B., ZUCCHELLI D.
- Date : 08/10/2009
- Langues : Italien
- Source : Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Formats : PDF
Voir la fiche
-
Influenza del funzionamento a potenza ridotta s...
- Auteurs : SCHIBUOLA L.
- Date : 07/03/2002
- Langues : Italien
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
Voir la fiche
-
General-purpose variable-speed drive and motor ...
- Auteurs : LOWERY T. F.
- Date : 1998
- Langues : Anglais
- Source : ASHRAE Transactions. 1998 annual Meeting, Toronto, Ontario + CD-ROM.
Voir la fiche
-
Effect of inlet duct and damper design on fan p...
- Auteurs : HOSSAIN M. Y., BACH C. K., SAN O.
- Date : 09/07/2018
- Langues : Anglais
- Source : 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
THE PERFORMANCE OF A CONTINUOUS LINEAR DIFFUSER...
- Auteurs : HART G. H., INT-HOUT D.
- Date : 1981
- Langues : Anglais
Voir la fiche