Diffuseur d'air et efficacité de la ventilation.
Terminali per la diffusione dell'aria ed efficienza di ventilazione.
Auteurs : BASSO R. A.
Résumé
The ventilation rate provided in the Standard UNI 10339 leaves the kind of installation and the air diffusion system out of consideration; in fact the ventilation rate really involved in internal pollutant dilution fluctuates as a function of the air-diffusion system. To consider this effect, in the reviewing of the standard, the concept of ventilation effectiveness has been introduced; it supplies a type of measurement of the ventilation air flow really used for indoor pollutant dilution, compared with the total supply air flow. As use of a qualitative index to express pollutant dilution would be difficult to carry out, a thermal index designed to put the diffuser air induction performance in touch with the air mixing one is proposed. Ventilation effectiveness becomes a parameter for air diffuser selection that considers their performances, in order to achieve the best indoor air quality.
Détails
- Titre original : Terminali per la diffusione dell'aria ed efficienza di ventilazione.
- Identifiant de la fiche : 2006-2007
- Langues : Italien
- Sujet : Réglementation
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
- Date d'édition : 07/03/2002
Liens
Voir d'autres communications du même compte rendu (32)
Voir le compte rendu de la conférence
Indexation
-
Les travaux de normalisation européenne sur la ...
- Auteurs : BERNARD A. M.
- Date : 04/1999
- Langues : Français
- Source : Chauff. Vent. Cond. Air - n. 4
Voir la fiche
-
LA RECUPERATION DE LA CHALEUR EN CONDITIONS DE ...
- Auteurs : BORCHIELLINI R., MARANO A.
- Date : 09/1987
- Langues : Italien
- Source : Cond. Aria - vol. 31 - n. 9
Voir la fiche
-
Essais acoustiques d'installations de condition...
- Date : 10/1996
- Langues : Italien
- Source : Termotecnica - vol. 50 - n. 8
Voir la fiche
-
THE PERFORMANCE OF A CONTINUOUS LINEAR DIFFUSER...
- Auteurs : HART G. H., INT-HOUT D.
- Date : 1981
- Langues : Anglais
Voir la fiche
-
Influenza del funzionamento a potenza ridotta s...
- Auteurs : SCHIBUOLA L.
- Date : 07/03/2002
- Langues : Italien
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
Voir la fiche