Influence du fonctionnement à charge partielle sur la performance saisonnière des conditionneurs d'air.
Influenza del funzionamento a potenza ridotta sulle prestazioni stagionali di condizionatori d'aria.
Auteurs : SCHIBUOLA L.
Résumé
The advantages of a correct prediction of the seasonal energy consumption of HVAC systems are multiple. First of all the capability to estimate the energy and economic cost of the management of these plants when confronted with different design options about the building-plant system. The performance of an HVAC system derives not only from the operative thermal levels, but also from the building requirement trend which normally involves frequent reduction of the full capacity. Nowadays, awareness of the importance of part-load working influence on the equipment efficiency is rising. The consequence is the introduction (Italian standard UNI 10963) or the modification of the standards used in testing the equipment under part-load conditions in order to better understand and quantify the part load influence. This paper presents the procedures and the results from their use for the simulation of the building-plant system in order to evaluate the long-term performances of split systems with on-off or modulating control.
Détails
- Titre original : Influenza del funzionamento a potenza ridotta sulle prestazioni stagionali di condizionatori d'aria.
- Identifiant de la fiche : 2006-1419
- Langues : Italien
- Sujet : Réglementation
- Source : Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
- Date d'édition : 07/03/2002
Liens
Voir d'autres communications du même compte rendu (32)
Voir le compte rendu de la conférence
-
Calcolo delle prestazioni di unità di condizion...
- Auteurs : SCHIBUOLA L.
- Date : 09/2002
- Langues : Italien
- Source : Termotecnica - vol. 56 - n. 7
Voir la fiche
-
Method of testing for rating room air condition...
- Date : 03/1998
- Langues : Anglais
- Source : ASHRAE Stand. - BSR-ASHRAE 16-1983 (RA); 9 p.; 5 fig.; 2 tabl.; 3 ref.; append.
Voir la fiche
-
Method of testing for rating room air condition...
- Auteurs : ASHRAE
- Date : 1999
- Langues : Anglais
Voir la fiche
-
2008 Standard for performance rating of forced-...
- Auteurs : AHRI
- Date : 2008
- Langues : Anglais
Voir la fiche
-
Methods of testing for rating room fan-coil air...
- Date : 1991
- Langues : Anglais
- Source : ASHRAE Stand. - ANSI-ASHRAE Stand. 79-1984 (RA 91); 14 p.; 10 fig.; 2 tabl.; 3 ref.