Supply air terminal devices and ventilation effectiveness.
Terminali per la diffusione dell'aria ed efficienza di ventilazione.
Author(s) : BASSO R. A.
Summary
The ventilation rate provided in the Standard UNI 10339 leaves the kind of installation and the air diffusion system out of consideration; in fact the ventilation rate really involved in internal pollutant dilution fluctuates as a function of the air-diffusion system. To consider this effect, in the reviewing of the standard, the concept of ventilation effectiveness has been introduced; it supplies a type of measurement of the ventilation air flow really used for indoor pollutant dilution, compared with the total supply air flow. As use of a qualitative index to express pollutant dilution would be difficult to carry out, a thermal index designed to put the diffuser air induction performance in touch with the air mixing one is proposed. Ventilation effectiveness becomes a parameter for air diffuser selection that considers their performances, in order to achieve the best indoor air quality.
Details
- Original title: Terminali per la diffusione dell'aria ed efficienza di ventilazione.
- Record ID : 2006-2007
- Languages: Italian
- Subject: Regulation
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
- Publication date: 2002/03/07
Links
See other articles from the proceedings (32)
See the conference proceedings
Indexing
-
Filtrazione e purificazione dell'aria tra evolu...
- Author(s) : GENGHINI B., ZUCCHELLI D.
- Date : 2009/10/08
- Languages : Italian
- Source: Impianti, energia e ambiente costruito: verso un benessere sostenibile. Atti 47° Congresso Internazionale AICARR: 8-9 ottobre 2009, Tivoli-Roma./ Systems, energy and built environment: toward a sustainable comfort. Proceedings 47th International Congress of AICARR: October 8-9, 2009, Tivoli-Rome.
- Formats : PDF
View record
-
Influenza del funzionamento a potenza ridotta s...
- Author(s) : SCHIBUOLA L.
- Date : 2002/03/07
- Languages : Italian
- Source: Qualità ambientale e soluzioni sostenibili. 43e Convegno Internazionale AICARR [CD-ROM]./ Environmental quality and sustainable technology. 43rd International conference of AICARR [CD-ROM].
View record
-
General-purpose variable-speed drive and motor ...
- Author(s) : LOWERY T. F.
- Date : 1998
- Languages : English
- Source: ASHRAE Transactions. 1998 annual Meeting, Toronto, Ontario + CD-ROM.
View record
-
Effect of inlet duct and damper design on fan p...
- Author(s) : HOSSAIN M. Y., BACH C. K., SAN O.
- Date : 2018/07/09
- Languages : English
- Source: 2018 Purdue Conferences. 17th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
View record
-
Norma de ensayo PREN 17625 “roof top units—test...
- Author(s) : MUNOZ SANCHEZ F., CONDE BLANCO J.
- Date : 2022/04
- Languages : Spanish
- Source: XI Congreso Ibérico y IX Congreso Iberoamericano de Ciencias y Técnicas del Frío, CYTEF 2022.
- Formats : PDF
View record