Document IIF
Distribution de la charge en frigorigène dans une pompe à chaleur saumure/eau utilisant le R290 comme frigorigène.
Refrigerant charge distribution in brine-to-water heat pump using R290 as refrigerant.
Auteurs : SANCHEZ MORENO GINER L., METHLER T., BARCELÓ RUESCAS F., GONZÁLVEZ-MACIÁ J.
Type d'article : Article de la RIF
Résumé
This paper presents experimental results from a brine-to-water heat pump used for space heating at low temperature, with a low refrigerant charge of R290 (propane). Performance and refrigerant distribution were analysed in every test condition studied. Performance results show a declared heating capacity of 9.5 kW, obtaining a specific capacity of 48.7 kW rmkg and a seasonal coefficient of performance of 4.01. In terms of refrigerant distribution, at the nominal point, 41.5% of the refrigerant is located in the compressor, mainly dissolved in the oil, and the rest is separated almost evenly in both heat exchangers, 23.9% in the condenser and 27.8% in the evaporator; having the lines and accessories (pneumatic-ball valves) the remaining 6.8%. Due to this fact, reducing oil solubility by heating the crankcase or increasing the superheat (SH) has a positive impact on the refrigerant charge reduction, but it also affects the coefficient of performance.
Documents disponibles
Format PDF
Pages : 158-167
Disponible
Prix public
20 €
Prix membre*
Gratuit
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Refrigerant charge distribution in brine-to-water heat pump using R290 as refrigerant.
- Identifiant de la fiche : 30030805
- Langues : Anglais
- Sujet : Technologie
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 145
- Date d'édition : 01/2023
- DOI : http://dx.doi.org/10.1016/j.ijrefrig.2022.10.013
Liens
Voir d'autres articles du même numéro (45)
Voir la source
-
Influence of the refrigerant charge in an R407C...
- Auteurs : SIERES J., ORTEGA I., CERDEIRA F., et al.
- Date : 02/2020
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 110
- Formats : PDF
Voir la fiche
-
Refrigerant mass distribution in an invertible ...
- Auteurs : GUZZARDI C., AZZOLIN M., LAZZARATO S., DEL COL D.
- Date : 06/2022
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 138
- Formats : PDF
Voir la fiche
-
Charge reduction analysis in a water-cooling ma...
- Auteurs : DI DONATO L., MUGNINI A., CARESANA F., POLONARA F., ARTECONI A.
- Date : 03/2025
- Langues : Anglais
- Source : International Journal of Refrigeration - Revue Internationale du Froid - vol. 171
- Formats : PDF
Voir la fiche
-
Effects of refrigerant charge and structural pa...
- Auteurs : ZHANG D., WU Q. B., LI J. P., et al.
- Date : 12/2014
- Langues : Anglais
- Source : Applied Thermal Engineering - vol. 73 - n. 1
Voir la fiche
-
Low charge ammonia systems.
- Auteurs : RAGHAVAN K.
- Date : 01/2017
- Langues : Anglais
- Source : Air Conditioning and Refrigeration Journal, Cold Chain - vol. 8 - n. 1
- Formats : PDF
Voir la fiche