Effet de choc d'une gouttelette sur une surface froide : mesure de la température d'interface en temps réel à l'aide d'un laser.

Real-time laser-based measurement of interface temperature during droplet impingement on a cold surface.

Auteurs : CHEN Q., LI Y., LONGTIN J. P.

Type d'article : Article

Résumé

This work presents a laser-based thermoreflectance technique to measure the real-time change in temperature of a liquid-solid interface when a heated liquid droplet impinges on a transparent substrate. Temperature variation at the interface results in refractive index changes in both the liquid and substrate, which, in turn, cause a reflectivity change at the interface. A 5 mW HeNe laser and a silicon photodiode are used to monitor the real-time reflectivity of the interface. The test and the results obtained are presented.

Détails

  • Titre original : Real-time laser-based measurement of interface temperature during droplet impingement on a cold surface.
  • Identifiant de la fiche : 2003-1704
  • Langues : Anglais
  • Source : International Journal of Heat and Mass Transfer - vol. 46 - n. 5
  • Date d'édition : 02/2003

Liens


Voir d'autres articles du même numéro (4)
Voir la source