Résumé
A simulation model for CO2 air-conditioning system in vehicle was developed in this paper. The model was used to investigate the effect of throttle tube flow area on the performance of CO2 air-conditioning system. The simulation results showed that under city condition, the operation state of CO2 air conditioning was affected by the throttle tube flow area significantly. The system condensation pressure could be too large and the system could not work stably when the throttle tube flow area was too small. The coefficient of performance (COP) of CO2 air-conditioning system would decrease appreciably when the throttle tube flow area increased from 0.5 to 1.3 mm2. There existed a maximum system cooling capacity with the throttle tube flow area increasing from 0.5 to 1.3 mm2. When the orifice flow area was 1 mm2, the CO2 air-conditioning system would achieve a maximum cooling capacity.
Documents disponibles
Format PDF
Pages : 5 p.
Disponible
Prix public
20 €
Prix membre*
15 €
* meilleur tarif applicable selon le type d'adhésion (voir le détail des avantages des adhésions individuelles et collectives)
Détails
- Titre original : Effects of throttle tube flow area on performance of CO2 mobile air-conditioning system.
- Identifiant de la fiche : 30005463
- Langues : Anglais
- Source : ACRA2010. Asian conference on refrigeration and air conditioning: Tokyo, Japan, June 7-9, 2010.
- Date d'édition : 07/06/2010
Liens
Voir d'autres communications du même compte rendu (107)
Voir le compte rendu de la conférence
Indexation
-
Thèmes :
Systèmes de détente;
CO2;
Conditionnement d'air mobile - Mots-clés : Automobile; R744; Simulation; Performance; Écoulement; COP; Frigorigène; Conditionnement d'air; CO2
-
Sistemas típicos para automoción: simulación de...
- Auteurs : ZILIO C., BROWN J. S., CAVALLINI A.
- Date : 10/2010
- Langues : Espagnol
- Source : IIF-IIR/Frío Calor Aire acond. - vol. 38 - n. 429
- Formats : PDF
Voir la fiche
-
Simulation of R1234yf performance in a typical ...
- Auteurs : ZILIO C., BROWN J. S., CAVALLINI A.
- Date : 23/06/2009
- Langues : Anglais
- Source : 3rd Conference on Thermophysical Properties and Transfer Processes of Refrigerants
- Formats : PDF
Voir la fiche
-
Är R1234yf framtidens kölmedium för mobilkyla?
- Auteurs : MAKHNATCH P., KHODABANDEH R., PALM B.
- Date : 2013
- Langues : Suédois
- Source : KYLA+ Värmepumpar - n. 1
Voir la fiche
-
Chances and limitations of a hybrid refrigerant...
- Auteurs : HESSE U.
- Date : 14/07/2014
- Langues : Anglais
- Source : 2014 Purdue Conferences. 15th International Refrigeration and Air-Conditioning Conference at Purdue.
- Formats : PDF
Voir la fiche
-
Experimental evaluation of the optimal refriger...
- Auteurs : LIU H., CHEN J., CHEN Z., et al.
- Date : 01/08/2004
- Langues : Anglais
- Source : Natural Working Fluids 2004: 6th IIR-Gustav Lorentzen Conference
- Formats : PDF
Voir la fiche